Literature DB >> 11300507

Sweat testing of MDMA with the Drugwipe analytical device: a controlled study with two volunteers.

R Pacifici1, M Farré, S Pichini, J Ortuño, P N Roset, P Zuccaro, J Segura, R de la Torre.   

Abstract

Rapid on-site tests for the analysis of drugs of abuse in unconventional specimens (e.g., sweat) have recently been developed. Two healthy volunteers familiar with the effects of methylenedioxymethamphetamine (MDMA) were given 100 mg of the drug as a single oral dose. MDMA and its main metabolite 4-hydroxy-3-methoxymethamphetamine (HMMA) were determined in plasma and urine by gas chromatography-mass spectrometry (GC-MS). MDMA was also investigated in sweat with the Drugwipe (an immunochemical strip test). Subjects' armpits were swabbed for 10 s at 0 time (predose) and at 2, 6, 8, 12, and 24 h after MDMA administration. MDMA consumption could be detected using Drugwipe at 2 h and for as long as 12 h after drug administration. However, in one of the volunteers, a faint color change appeared at 0 time, when plasma and urine tested negative for MDMA and did not disappear even 48 h later. Plasma concentrations of MDMA and HMMA measured by GC-MS peaked at 2-4 h, and values greater than 20 ng/mL for MDMA and of 40 ng/mL for HMMA were still detected at 24 h. Urine tested positive by GC-MS for MDMA and HMMA in the 48-h collection period. These findings preliminarily support sweat testing with Drugwipe for monitoring MDMA use.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11300507     DOI: 10.1093/jat/25.2.144

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  5 in total

1.  3,4-methylenedioxymethamphetamine (MDMA--Ecstasy) decreases neutrophil activity through the glucocorticoid pathway and impairs host resistance to Listeria monocytogenes infection in mice.

Authors:  V Ferraz-de-Paula; A Ribeiro; J Souza-Queiroz; M L Pinheiro; J F Vecina; D P M Souza; W M Quinteiro-Filho; R L M Moreau; M L S Queiroz; J Palermo-Neto
Journal:  J Neuroimmune Pharmacol       Date:  2014-08-12       Impact factor: 4.147

Review 2.  3,4-methylenedioxymethamphetamine (MDMA): a review.

Authors:  G O'Leary; J Nargiso; R D Weiss
Journal:  Curr Psychiatry Rep       Date:  2001-12       Impact factor: 8.081

Review 3.  Lateral flow assays.

Authors:  Katarzyna M Koczula; Andrea Gallotta
Journal:  Essays Biochem       Date:  2016-06-30       Impact factor: 8.000

4.  In vitro validation of the tear matrix metalloproteinase 9 in-situ immunoassay.

Authors:  Seung Pil Bang; Myeong Jin Son; Harim Kim; You Hyun Lee; Jong Hwa Jun
Journal:  Sci Rep       Date:  2020-09-15       Impact factor: 4.379

5.  Rapid Multiplexed Detection on Lateral-Flow Devices Using a Laser Direct-Write Technique.

Authors:  Peijun J W He; Ioannis N Katis; Robert W Eason; Collin L Sones
Journal:  Biosensors (Basel)       Date:  2018-10-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.