Literature DB >> 11300460

Assessment of aortic regurgitation by transesophageal color Doppler imaging of the vena contracta: validation against an intraoperative aortic flow probe.

D L Willett1, S A Hall, M E Jessen, M A Wait, P A Grayburn.   

Abstract

OBJECTIVES: This study was performed to validate the accuracy of color flow vena contracta (VC) measurements of aortic regurgitation (AR) severity by comparing them to simultaneous intraoperative flow probe measurements of regurgitant fraction (RgF) and regurgitant volume (RgV).
BACKGROUND: Color Doppler imaging of the vena contracta has emerged as a simple and reliable measure of the severity of valvular regurgitation. This study evaluated the accuracy of VC imaging of AR by transesophageal echocardiography (TEE).
METHODS: A transit-time flow probe was placed on the ascending aorta during cardiac surgery in 24 patients with AR. The flow probe was used to measure RgF and RgV simultaneously during VC imaging by TEE. Flow probe and VC imaging were interpreted separately and in blinded fashion.
RESULTS: A good correlation was found between VC width and RgF (r = 0.85) and RgV (r = 0.79). All six patients with VC width >6 mm had a RgF >0.50. All 18 patients with VC width <5 mm had a RgF <0.50. Vena contracta area also correlated well with both RgF (r = 0.81) and RgV (r = 0.84). All six patients with VC area >7.5 mm2 had a RgF >0.50, and all 18 patients with a VC area <7.5 mm2 had a RgF <0.50. In a subset of nine patients who underwent afterload manipulation to increase diastolic blood pressure, RgV increased significantly (34 +/- 26 ml to 41 +/- 27 ml, p = 0.042) while VC width remained unchanged (5.4 +/- 2.8 mm to 5.4 +/- 2.8 mm, p = 0.41).
CONCLUSIONS: Vena contracta imaging by TEE color flow mapping is an accurate marker of AR severity. Vena contracta width and VC area correlate well with RgF and RgV obtained by intraoperative flow probe. Vena contracta width appears to be less afterload-dependent than RgV.

Entities:  

Mesh:

Year:  2001        PMID: 11300460     DOI: 10.1016/s0735-1097(01)01114-7

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

Review 1.  Vena contracta width measurement: theoretic basis and usefulness in the assessment of valvular regurgitation severity.

Authors:  Jean Paul Quéré; Christophe Tribouilloy; Maurice Enriquez-Sarano
Journal:  Curr Cardiol Rep       Date:  2003-03       Impact factor: 2.931

Review 2.  Intraoperative echocardiography in valvular heart disease: an evidence-based appraisal.

Authors:  Hector I Michelena; Martin D Abel; Rakesh M Suri; William K Freeman; Roger L Click; Thoralf M Sundt; Hartzell V Schaff; Maurice Enriquez-Sarano
Journal:  Mayo Clin Proc       Date:  2010-07       Impact factor: 7.616

3.  Turbulence in the left ventricular outflow tract caused by an eccentric mitral inflow jet masquerades as aortic regurgitation.

Authors:  Paul Y Paik; Michelle Capdeville; Andra E Duncan
Journal:  Anesth Analg       Date:  2014-01       Impact factor: 5.108

4.  Severity of aortic regurgitation assessed by area of vena contracta: a clinical two-dimensional and three-dimensional color Doppler imaging study.

Authors:  Hirotomo Sato; Tetsuro Ohta; Kimiko Hiroe; Seiji Okada; Koji Shimizu; Rinji Murakami; Kazuaki Tanabe
Journal:  Cardiovasc Ultrasound       Date:  2015-05-05       Impact factor: 2.062

  4 in total