Literature DB >> 11300443

Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE Trial.A Stent vs. Stent Ultrasound Remodeling Evaluation.

Y Kobayashi1, Y Honda, G L Christie, P S Teirstein, S R Bailey, C L Brown, R V Matthews, A C De Franco, R S Schwartz, S Goldberg, J J Popma, P G Yock, P J Fitzgerald.   

Abstract

OBJECTIVES: We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time.
BACKGROUND: Preclinical studies have suggested that self-expanding stents may produce less vessel wall injury at initial deployment, leading to larger follow-up lumens than with balloon-expandable stents. However, the influence of the chronic stimulus from self-expanding stents on the vessel wall remains unknown.
METHODS: Sixty-two patients were randomly assigned to either the RADIUS self-expanding stent group (n = 32) or the Palmaz-Schatz balloon-expandable stent group (n = 30). Intravascular ultrasound was performed after stent deployment and at six-month follow-up.
RESULTS: At follow-up, the RADIUS stents had increased 23.6% in overall volume, while the Palmaz-Schatz stents had remained unchanged. Due to the greater mean neointimal area (3.0 +/- 1.7 mm2 vs. 1.9 +/- 1.2 mm2, p = 0.02) in the RADIUS group, no significant difference in net late lumen loss was observed between the two groups. On the other hand, analysis at the peristent margins demonstrated that mean late loss was significantly smaller in the RADIUS group than it was in the Palmaz-Schatz group (0.1 +/- 2.1 mm2 vs. 1.9 +/- 2.4 mm2, p = 0.02).
CONCLUSIONS: Serial volumetric IVUS revealed that the RADIUS stents continued to enlarge during the follow-up period. In this stent implantation protocol, this expansion was accompanied by a greater amount of neointima than the Palmaz-Schatz stents, resulting in similar late lumen loss in both configurations. In the peristent margins, however, late lumen loss was minimized with the RADIUS stents.

Entities:  

Mesh:

Year:  2001        PMID: 11300443     DOI: 10.1016/s0735-1097(01)01162-7

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  6 in total

1.  Novel 3D-CT evaluation of carotid stent volume: greater chronological expansion of stents in patients with vulnerable plaques.

Authors:  Hisakazu Itami; Koji Tokunaga; Yu Okuma; Tomohito Hishikawa; Kenji Sugiu; Kentaro Ida; Isao Date
Journal:  Neuroradiology       Date:  2013-07-03       Impact factor: 2.804

Review 2.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

3.  Long-term changes after carotid stenting assessed by intravascular ultrasound and near-infrared spectroscopy.

Authors:  Cyril Štěchovský; Petr Hájek; Robert Roland; Martin Horváth; Josef Veselka
Journal:  Cardiovasc Diagn Ther       Date:  2021-12

4.  Prospective randomized trial comparing a nitinol self-expanding coronary stent with low-pressure dilatation and a high-pressure balloon expandable bare metal stent.

Authors:  Shinichiro Tanaka; Sachiro Watanabe; Hitoshi Matsuo; Tomonori Segawa; Makoto Iwama; Takeshi Hirose; Haruki Takahashi; Koji Ono; Shunichiro Warita; Tai Kojima; Shinya Minatoguchi; Hisayoshi Fujiwara
Journal:  Heart Vessels       Date:  2008-02-14       Impact factor: 2.037

5.  Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model.

Authors:  Yutaka Hikichi; Mitsuo Umezu; Koichi Node; Kiyotaka Iwasaki
Journal:  Cardiovasc Interv Ther       Date:  2016-03-11

6.  Comparison of sirolimus and paclitaxel-eluting stents for complex coronary lesions: an intravascular ultrasound study.

Authors:  Yun-Kyeong Cho; Seung-Ho Hur; Hyun-Tae Kim; In-Cheol Kim; Hyoung-Seob Park; Hyuck-Jun Yoon; Chang-Wook Nam; Hyungseop Kim; Seong-Wook Han; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  Korean J Intern Med       Date:  2009-11-27       Impact factor: 2.884

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.