Long-term results with St. Jude Medical and CarboMedics prosthetic heart valves.

B C Chang1, S H Lim, D K Kim, J Y Seo, S Y Cho, W H Shim, N Chung, S S Kim, B K Cho.   

Abstract

BACKGROUND AND AIM OF THE STUDY: The clinical evaluation and comparison of St. Jude Medical (SJM) and CarboMedics (CM) prosthetic heart valves implanted between 1988 and 1997 is presented.
METHODS: In total, 648 SJM valves were implanted in 641 patients, and 601 CM valves in 591 patients. There were 684 mitral valve replacements, 256 aortic valve replacements, 252 mitral and aortic (double) valve replacements, 16 triple valve replacements, and 41 other tricuspid-related valve replacements. Total follow up was 98%. The overall incidence of valve-related events was compared before and after establishment of a 'valve clinic' in 1993.
RESULTS: The overall hospital mortality was 3.4%; late mortality was 8.2%. The five- and ten-year survival for all patients was 92.1% and 86.2%, respectively. There were 31 episodes of thromboembolism in 27 patients (including valve thrombosis in three), 21 episodes of bleeding events in 20 patients, and 18 re-replacements of implanted valves. No structural valve deterioration was observed. Freedom from thromboembolism was 97.8% at five years and 96.3% at ten years; freedom from bleeding episodes was 98.1% and 97.6%, respectively. In terms of hospital and late mortality, and incidence of thromboembolism, hemorrhagic episodes and structural valve failure, no statistically significant differences were found between the SJM and CarboMedics patient groups. Freedom from thromboembolism was 96.7% at five years before initiation of an intensive follow up program, and 99.0% thereafter (p = 0.031). In contrast, freedom from bleeding episodes fell from 99.3% to 96.1% during the same time period (p = 0.0004).
CONCLUSION: Both the SJM and CM prosthetic heart valves performed well in our study, and no discernible differences in clinical performance of the two valves were detected. The intensive follow up program resulted in a reduced incidence of thromboembolism, but an increased number of bleeding complications. An optimum anticoagulation regimen to manage these two conflicting problems has yet to be elucidated.

Entities:  

Mesh:

Year:  2001        PMID: 11297205

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  4 in total

1.  Long-term results of bioprosthetic tricuspid valve replacement: an analysis of 25 years of experience.

Authors:  Naoto Morimoto; Syunsuke Matsushima; Masaya Aoki; Soichiro Henmi; Naritomo Nishioka; Hirohisa Murakami; Tasuku Honda; Keitaro Nakagiri; Masato Yoshida; Nobuhiko Mukohara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-12-06

2.  Hemodynamic Performance and Thrombogenic Properties of a Superhydrophobic Bileaflet Mechanical Heart Valve.

Authors:  David L Bark; Hamed Vahabi; Hieu Bui; Sanli Movafaghi; Brandon Moore; Arun K Kota; Ketul Popat; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2016-04-20       Impact factor: 3.934

3.  A turbulence in vitro assessment of On-X and St Jude Medical prostheses.

Authors:  Hoda Hatoum; Pablo Maureira; Lakshmi Prasad Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2019-02-21       Impact factor: 5.209

4.  Flow dynamics of surgical and transcatheter aortic valves: Past to present.

Authors:  Hoda Hatoum; Sunyoung Ahn; Scott Lilly; Pablo Maureira; Juan Crestanello; Vinod H Thourani; Lakshmi Prasad Dasi
Journal:  JTCVS Open       Date:  2022-01-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.