Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablation.

S Tungjitkusolmun1, V R Vorperian, N Bhavaraju, H Cao, J Z Tsai, J G Webster.   

Abstract

We used the finite element method to study the effect of radio-frequency (RF) catheter ablation on tissue heating and lesion formation at different intracardiac sites exposed to different regional blood velocities. We examined the effect of application of RF current in temperature- and power-controlled mode above and beneath the mitral valve annulus where the regional blood velocities are high and low respectively. We found that for temperature-controlled ablation, more power was delivered to maintain the preset tip temperature at sites of high local blood velocity than at sites of low local blood velocity. This induced more tissue heating and larger lesion volumes than ablations at low velocity regions. In contrast, for power-controlled ablation, tissue heating was less at sites of high compared with low local blood velocity for the same RF power setting. This resulted in smaller lesion volumes at sites of low local velocity. Our numerical analyzes showed that during temperature-controlled ablation at 60 degrees C, the lesion volumes at sites above and underneath the mitral valve were comparable when the duration of RF current application was 10 s. When the duration of RF application was extended to 60 s and 120 s, lesion volumes were 33.3% and 49.4% larger above the mitral valve than underneath the mitral valve. Also, with temperature-controlled ablation, tip temperature settings of 70 degrees C or greater were associated with a risk of tissue overheating during long ablations at high local blood velocity sites. In power-controlled ablation (20 W), the lesion volume formed underneath the mitral valve was 165.7% larger than the lesion volume above the mitral valve after 10 s of ablation. We summarized the guidelines for energy application at low and high flow regions.

Entities:  

Mesh:

Year:  2001        PMID: 11296875     DOI: 10.1109/10.909640

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

1.  Considerations for thermal injury analysis for RF ablation devices.

Authors:  Isaac A Chang
Journal:  Open Biomed Eng J       Date:  2010-02-04

Review 2.  Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future.

Authors:  Enrique J Berjano
Journal:  Biomed Eng Online       Date:  2006-04-18       Impact factor: 2.819

3.  In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals.

Authors:  Chanchana Tangwongsan; Louay Chachati; John G Webster; Patrick V Farrell
Journal:  Biomed Eng Online       Date:  2006-10-26       Impact factor: 2.819

4.  Modeling Left Atrial Flow, Energy, Blood Heating Distribution in Response to Catheter Ablation Therapy.

Authors:  Desmond Dillon-Murphy; David Marlevi; Bram Ruijsink; Ahmed Qureshi; Henry Chubb; Eric Kerfoot; Mark O'Neill; David Nordsletten; Oleg Aslanidi; Adelaide de Vecchi
Journal:  Front Physiol       Date:  2018-12-14       Impact factor: 4.566

5.  Contact geometry affects lesion formation in radio-frequency cardiac catheter ablation.

Authors:  Neal Gallagher; Elise C Fear; Israel A Byrd; Edward J Vigmond
Journal:  PLoS One       Date:  2013-09-23       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.