Dual energy X-ray absorptiometry in small rats with low bone mineral density.

M M Petersen1, P K Nielsen, E Lewin, K Olgaard.   

Abstract

The feasibility of dual energy X-ray absorptiometry (DXA) using the Norland XR-26 Mark II bone densitometer for measurements of bone mineral content (BMC) and bone mineral density (BMD) in small rats was evaluated. Thirty-two young, isogenic, Lewis rats (weights from 119 g to 227 g) were used; normal rats (n = 7) and rats with low BMD obtained from three different vitamin D-depleted models (n = 25). DXA measurements were performed using the special software for small animals. Duplicate scans of excised femurs performed at 2 mm/second (pixel size of 0.5 mm x 0.5 mm) were very precise measurements with a coefficient of variation (CV) below 1.6% in animals with normal BMD; in rats with low BMD, the CV was significantly higher (P = 0.02-0.04), 7.8% and 4.4% for BMC and BMD, respectively. Regression analysis demonstrated that these measurements were related to the ash weight (R2 > 98.6%). The CV for measurements of the lumbar spine at 10 mm/second (pixel size 0.5 mm x 0.5 mm) was 2.6% and 2.2% for BMC and BMD, respectively in rats with normal BMD, and again higher (P = 0.03-0.14) in rats with low BMD, 7.3% and 4.7%, respectively, for BMC and BMD. Even though low CVs were obtained for total body duplicate scans (scan speed of 20 mm/second and a pixel size of 1.5 mm x 1.5 mm), the measurements were problematic for accuracy because of an overestimation of both BMC and the area of bone. Using these scan parameters the measurements of total body bone mineral could not be recommended in small rats with low BMD.

Entities:  

Mesh:

Year:  2000        PMID: 11289694     DOI: 10.1007/s002230001176

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  2 in total

1.  Prospective use of dual-energy X-ray absorptiometry in a model of immobilization and exercise in rats: the preliminary results.

Authors:  Ayce Atalay; Murat Yildirim; Yesim Gokce-Kutsal; Rustu Onur; Macit Ariyurek
Journal:  Rheumatol Int       Date:  2008-02-13       Impact factor: 2.631

2.  Bone mineral measurements of subchondral and trabecular bone in healthy and osteoporotic rabbits.

Authors:  S Castañeda; R Largo; E Calvo; F Rodríguez-Salvanés; M E Marcos; M Díaz-Curiel; G Herrero-Beaumont
Journal:  Skeletal Radiol       Date:  2005-10-25       Impact factor: 2.199

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.