Literature DB >> 11289414

Self-referencing ceramic-based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes.

J J Burmeister1, G A Gerhardt.   

Abstract

A self-referencing technique utilizing two microelectrodes on a ceramic-based multisite array is employed for confirmation and elimination of interferences detected by enzyme-based microelectrodes. The measurement of L-glutamate using glutamate oxidase was the test system; however, other oxidase enzymes such as glucose oxidase can be employed. One recording site was coated with Nafion with L-glutamate oxidase and bovine serum albumin (BSA) cross-linked with glutaraldehyde while the other had Nafion with BSA cross-linked with glutaraldehyde. Differences in the chemistry of the two recording sites allowed for identification and elimination of interfering signals to be removed from the analyte response. The electrode showed low detection limits (LOD = 0.98 +/- 0.09 microM, signal-to-noise ratio of 3), fast response times (T90 approximately 1 s), and excellent linearity (R2 = 0.999 +/- 0.000) over the concentration range of 0-200 microM for calibrations of L-glutamate in vitro. The selectivity and dimensions of the multisite electrode allow in vivo glutamate measurements. This electrode has been applied to in vivo measurements of the clearance of locally applied glutamate and release of glutamate in the prefrontal cortex of anesthetized rats. In addition, a aimilar approach has been applied to the development of a microelectrode for measures of glucose.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11289414     DOI: 10.1021/ac0010429

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  75 in total

1.  Hypersensitive glutamate signaling correlates with the development of late-onset behavioral morbidity in diffuse brain-injured circuitry.

Authors:  Theresa Currier Thomas; Jason M Hinzman; Greg A Gerhardt; Jonathan Lifshitz
Journal:  J Neurotrauma       Date:  2011-12-01       Impact factor: 5.269

2.  Ceramic-based microelectrode arrays: recording surface characteristics and topographical analysis.

Authors:  Pooja M Talauliker; David A Price; Jason J Burmeister; Silpa Nagari; Jorge E Quintero; Francois Pomerleau; Peter Huettl; J Todd Hastings; Greg A Gerhardt
Journal:  J Neurosci Methods       Date:  2011-04-12       Impact factor: 2.390

Review 3.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

4.  Voltammetric detection of hydrogen peroxide at carbon fiber microelectrodes.

Authors:  Audrey L Sanford; Stephen W Morton; Kelsey L Whitehouse; Hannah M Oara; Leyda Z Lugo-Morales; James G Roberts; Leslie A Sombers
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

5.  Aberrant glutamate signaling in the prefrontal cortex and striatum of the spontaneously hypertensive rat model of attention-deficit/hyperactivity disorder.

Authors:  Erin M Miller; Francois Pomerleau; Peter Huettl; Greg A Gerhardt; Paul E A Glaser
Journal:  Psychopharmacology (Berl)       Date:  2014-02-28       Impact factor: 4.530

6.  Simple Fabrication of Flexible Biosensor Arrays Using Direct Writing for Multianalyte Measurement from Human Astrocytes.

Authors:  James K Nolan; Tran N H Nguyen; Khanh Vy H Le; Luke E DeLong; Hyowon Lee
Journal:  SLAS Technol       Date:  2019-11-26       Impact factor: 3.047

7.  The role of glutamate signaling in incentive salience: second-by-second glutamate recordings in awake Sprague-Dawley rats.

Authors:  Seth R Batten; Francois Pomerleau; Jorge Quintero; Greg A Gerhardt; Joshua S Beckmann
Journal:  J Neurochem       Date:  2018-05-15       Impact factor: 5.372

8.  Using a common average reference to improve cortical neuron recordings from microelectrode arrays.

Authors:  Kip A Ludwig; Rachel M Miriani; Nicholas B Langhals; Michael D Joseph; David J Anderson; Daryl R Kipke
Journal:  J Neurophysiol       Date:  2008-12-24       Impact factor: 2.714

9.  Implantable microelectrode arrays for simultaneous electrophysiological and neurochemical recordings.

Authors:  Matthew D Johnson; Robert K Franklin; Matthew D Gibson; Richard B Brown; Daryl R Kipke
Journal:  J Neurosci Methods       Date:  2008-07-23       Impact factor: 2.390

10.  Using Enzyme-based Biosensors to Measure Tonic and Phasic Glutamate in Alzheimer's Mouse Models.

Authors:  Holly C Hunsberger; Sharay E Setti; Ryan T Heslin; Jorge E Quintero; Greg A Gerhardt; Miranda N Reed
Journal:  J Vis Exp       Date:  2017-05-03       Impact factor: 1.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.