Minimizing analyte electrolysis in an electrospray emitter.

V Kertesz1, G J Van Berkel.   

Abstract

The electrospray (ES) ion source is a controlled-current electrolytic flow cell. Electrolytic reactions in the ES emitter capillary are continually ongoing to sustain the production of charged droplets and ultimately gas-phase ions from this device. Under certain circumstances, the analytes under study may be directly involved in these electrolytic processes. It is demonstrated that a simple means to minimize analyte electrolysis is to exchange the normal metal emitter capillary of commercial ES sources with one made of fused silica. This change is shown to provide an ES mass spectrometric system of similar performance in terms of gas-phase ion signal generated for non-electroactive analytes and also assures minimal oxidation of electroactive analytes even at low (2.0 microl x min(-1)) solution flow-rates and high (millimolar) solution electrolyte concentrations.

Entities:  

Mesh:

Year:  2001        PMID: 11288203     DOI: 10.1002/jms.122

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  5 in total

1.  Surface-assisted reduction of aniline oligomers, N-phenyl-1,4-phenylenediimine and thionin in atmospheric pressure chemical ionization and atmospheric pressure photoionization.

Authors:  Vilmos Kertesz; BerkelGaryJ Van
Journal:  J Am Soc Mass Spectrom       Date:  2002-02       Impact factor: 3.109

2.  Efficient analyte oxidation in an electrospray ion source using a porous flow-through electrode emitter.

Authors:  Gary J Van Berkel; Vilmos Kertesz; Michael J Ford; Michael C Granger
Journal:  J Am Soc Mass Spectrom       Date:  2004-12       Impact factor: 3.109

3.  An open design microfabricated nib-like nanoelectrospray emitter tip on a conducting silicon substrate for the application of the ionization voltage.

Authors:  Séverine Le Gac; Christian Rolando; Steve Arscott
Journal:  J Am Soc Mass Spectrom       Date:  2005-12-15       Impact factor: 3.109

4.  Unexpected Reduction of Iminoquinone and Quinone Derivatives in Positive Electrospray Ionization Mass Spectrometry and Possible Mechanism Exploration.

Authors:  Jiying Pei; Cheng-Chih Hsu; Ruijie Zhang; Yinghui Wang; Kefu Yu; Guangming Huang
Journal:  J Am Soc Mass Spectrom       Date:  2017-08-07       Impact factor: 3.109

Review 5.  Generation of mass tags by the inherent electrochemistry of electrospray for protein mass spectrometry.

Authors:  Christophe Roussel; Loïc Dayon; Niels Lion; Tatiana C Rohner; Jacques Josserand; Joël S Rossier; Henrik Jensen; Hubert H Girault
Journal:  J Am Soc Mass Spectrom       Date:  2004-12       Impact factor: 3.109

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.