Literature DB >> 11288201

Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study.

D R Ifa1, M Falci, M E Moraes, F A Bezerra, M O Moraes, G de Nucci .   

Abstract

A rapid, sensitive and specific analytical method was developed and validated to quantify gabapentin in human plasma using acetaminophen as an internal standard. The method employs a single plasma protein precipitation. The analytes are chromatographed on a C4 reversed-phase chromatographic column and analyzed by mass spectrometry in the multiple reaction monitoring (MRM) mode. The method has a chromatographic run time of 4 min and a linear calibration curve over the range 50-10 000 ng x ml(-1) (r > 0.999). The between-run precision, based on the relative standard deviation for replicate quality controls, was < or = 4.8 % (200 ng x ml(-1)), 6.0% (1000 ng x ml(-1)) and 4.4% (5000 ng x ml(-1)). The between-run accuracy was +/-2.6, 4.4 and 0.5% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two gabentin capsule formulations (Progresse from Biosintética, Brazil, as a test formulation, and Neurotin from Parke-Davis, as a reference formulation) in 24 healthy volunteers of both sexes who received a single 300 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 7-day washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Progresse/Neurotin was 87.9-115.6% for AUC(0-36 h) and 88.6-111.7% for Cmax. Since both 90% CI for AUC(0-36 h) and Cmax were included in the 80-125% interval proposed by the US Food and Drug Administration, Progresse was considered bioequivalent to Neurotin according to both the rate and extent of absorption.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11288201     DOI: 10.1002/jms.120

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  4 in total

1.  Modern methods for analysis of antiepileptic drugs in the biological fluids for pharmacokinetics, bioequivalence and therapeutic drug monitoring.

Authors:  Juseop Kang; Yoo-Sin Park; Shin-Hee Kim; Sang-Hyun Kim; Min-Young Jun
Journal:  Korean J Physiol Pharmacol       Date:  2011-04-30       Impact factor: 2.016

2.  Therapeutic Drug Monitoring of the Newer Anti-Epilepsy Medications.

Authors:  Matthew D Krasowski
Journal:  Pharmaceuticals (Basel)       Date:  2010-06-11

3.  Development and validation of a rapid liquid chromatography/tandem mass spectrometry method to quantitate gabapentin and buprenorphine in human serum.

Authors:  Sarah J Phillips; Alison Oliveto; Michael J Mancino; Howard P Hendrickson
Journal:  Rapid Commun Mass Spectrom       Date:  2021-07-31       Impact factor: 2.586

Review 4.  An Updated Overview on Therapeutic Drug Monitoring of Recent Antiepileptic Drugs.

Authors:  Shery Jacob; Anroop B Nair
Journal:  Drugs R D       Date:  2016-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.