M A Arata1, H L Nisenbaum, T W Clark, M C Soulen. 1. Division of Interventional Radiology, Department of Radiology, University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.
Abstract
PURPOSE: The LeVeen radiofrequency (RF) probe uses roll-off of electrical impedance as the endpoint for RF cautery of hepatic tumors. The purpose of this study is to determine the relation of roll-off to local control of hepatic tumors. MATERIALS AND METHODS: Twenty hepatic tumors, including 10 hepatomas and 10 metastases, were treated. Lesions ranged from 1.4 cm to 6.0 cm in diameter; 13 (57%) were smaller than 3.0 cm. Each lesion was ablated with use of the LeVeen 15-gauge RF needle according to the manufacturer's protocol. Five patients underwent chemoembolization the day before. Patients were followed up with contrast-enhanced computed tomography or magnetic resonance imaging at 1 month and every 3 months thereafter. RESULTS: Among the 20 lesions, roll-off was achieved at all burn locations in 11 (55%), no burn locations in eight (40%), and two of three burn locations in one (5%). Roll-off was observed in all patients who had undergone chemoembolization the day before. Six local recurrences occurred, five after RF ablation without roll-off and one after RF ablation with roll-off. According to life-table analysis, the local recurrence rate at 6 months without roll-off was 43% and with roll-off was 15% (P =.024; OR = 8.3; 95% CI = 0.93-66). CONCLUSION: Roll-off is a significant predictor of local control after RF ablation. Strategies to enhance roll-off, such as concurrent embolization, may be important to optimize the therapeutic effect of this device.
PURPOSE: The LeVeen radiofrequency (RF) probe uses roll-off of electrical impedance as the endpoint for RF cautery of hepatic tumors. The purpose of this study is to determine the relation of roll-off to local control of hepatic tumors. MATERIALS AND METHODS: Twenty hepatic tumors, including 10 hepatomas and 10 metastases, were treated. Lesions ranged from 1.4 cm to 6.0 cm in diameter; 13 (57%) were smaller than 3.0 cm. Each lesion was ablated with use of the LeVeen 15-gauge RF needle according to the manufacturer's protocol. Five patients underwent chemoembolization the day before. Patients were followed up with contrast-enhanced computed tomography or magnetic resonance imaging at 1 month and every 3 months thereafter. RESULTS: Among the 20 lesions, roll-off was achieved at all burn locations in 11 (55%), no burn locations in eight (40%), and two of three burn locations in one (5%). Roll-off was observed in all patients who had undergone chemoembolization the day before. Six local recurrences occurred, five after RF ablation without roll-off and one after RF ablation with roll-off. According to life-table analysis, the local recurrence rate at 6 months without roll-off was 43% and with roll-off was 15% (P =.024; OR = 8.3; 95% CI = 0.93-66). CONCLUSION: Roll-off is a significant predictor of local control after RF ablation. Strategies to enhance roll-off, such as concurrent embolization, may be important to optimize the therapeutic effect of this device.
Authors: S Nahum Goldberg; Clement J Grassi; John F Cardella; J William Charboneau; Gerald D Dodd; Damian E Dupuy; Debra Gervais; Alice R Gillams; Robert A Kane; Fred T Lee; Tito Livraghi; John McGahan; David A Phillips; Hyunchul Rhim; Stuart G Silverman Journal: Radiology Date: 2005-04-21 Impact factor: 11.105
Authors: Paul F Laeseke; Lisa A Sampson; Dieter Haemmerich; Christopher L Brace; Jason P Fine; Tina M Frey; Thomas C Winter; Fred T Lee Journal: Radiology Date: 2006-08-23 Impact factor: 11.105
Authors: Antonio Orlacchio; Fabrizio Chegai; Costantino Del Giudice; Mariangela Massaccesi; Elisa Costanzo; Elena Di Caprera; Giovanni Simonetti Journal: Biomed Res Int Date: 2014-08-28 Impact factor: 3.411
Authors: Jin Woo Choi; Jeong Min Lee; Dong Ho Lee; Jeong-Hee Yoon; Kyung-Suk Suh; Jung-Hwan Yoon; Yoon Jun Kim; Jeong-Hoon Lee; Su Jong Yu; Joon Koo Han Journal: PLoS One Date: 2016-08-30 Impact factor: 3.240