Literature DB >> 11287514

Biocompatibility and performance of the Wallstent and several covered stents in a sheep iliac artery model.

M Cejna1, R Virmani, R Jones, H Bergmeister, U Losert, Z Xu, P Yang, M Schoder, J Lammer.   

Abstract

PURPOSE: To compare the biocompatibility and performance of various stent-grafts to those of a bare stent in an ovine model with a subchronic (3 months) endpoint.
MATERIALS AND METHODS: Three different types of stent-grafts (ePTFE/nitinol, n = 8; polyester/nitinol, n = 8; and polycarbonate urethane/cobalt-alloy, n = 8) and a bare stent as a control (Ni-Co-Ti-steel-alloy, n = 8) were implanted in the iliac arteries in eight female sheep. One type of each stent-graft was implanted per animal, two implants at each side. The implantation sites for each type varied from animal to animal. Angiographic control and intravascular ultrasound (IVUS) imaging were performed before and after implantation, after 2 months, and before explantation at 3 months and were used to characterize patency and to assess intimal hyperplasia. After 3 months, the implants were retrieved and subjected to histologic evaluation (after methacrylate embedding, cutting, and histologic staining) to characterize the biologic response.
RESULTS: Implantation was technically successful in all procedures. At 2 and 3 months after implantation, all segments in which stents had been implanted were patent. Marked neointima formation was found in the polyester-covered stent-graft that showed significant luminal narrowing of 50%, compared to the ePTFE-covered (24%) and polycarbonate urethane-covered endoprostheses (22%), as well as the bare stent (Wallstent; 9%; P < .001). A minimal inflammatory vessel wall reaction was demonstrated for the polyester-covered and ePTFE-covered endoprostheses; the polycarbonate urethane-covered stent-graft's response was demonstrable but not significantly different from that of the Wallstent. At 3 months, the ePTFE-covered stent-graft showed incomplete (>90%) endothelial coverage; in the other endoprostheses, complete but partially immature endothelialization was found.
CONCLUSION: All stent-grafts induced an inflammatory vessel wall reaction with neointimal hyperplasia. The polyester-covered endoprosthesis caused a marked reaction with 50% luminal stenosis. Endothelialization was retarded with the ePTFE-covered stent-graft. The bare stent performed best in regard to neointimal formation and caused the least inflammatory response.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11287514     DOI: 10.1016/s1051-0443(07)61916-2

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  7 in total

1.  Oxidized nickel-titanium foams for bone reconstructions: chemical and mechanical characterization.

Authors:  Maite Barrabés; Alexandra Michiardi; Conrado Aparicio; Pablo Sevilla; Josep A Planell; Francisco Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2007-07-10       Impact factor: 3.896

2.  Reduction of Ni release and improvement of the friction behaviour of NiTi orthodontic archwires by oxidation treatments.

Authors:  E Espinar; J M Llamas; A Michiardi; M P Ginebra; F J Gil
Journal:  J Mater Sci Mater Med       Date:  2011-03-25       Impact factor: 3.896

3.  Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress.

Authors:  Henry Y Chen; Anjan K Sinha; Jenny S Choy; Hai Zheng; Michael Sturek; Brian Bigelow; Deepak L Bhatt; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-09-16       Impact factor: 4.733

4.  Endovascular treatment of internal carotid and vertebral artery aneurysms using a novel pericardium covered stent.

Authors:  I Vulev; A Klepanec; R Bazik; T Balazs; R Illes; J Steno
Journal:  Interv Neuroradiol       Date:  2012-06-04       Impact factor: 1.610

5.  "Extarterectomy" for tumors invading the carotid artery: an animal model.

Authors:  Kazım Oner; Cem Bilgen; Ismail Oran; Tayfun Kirazli; Ahmet Memiş; Izzet Ovül; Ozlem Yilmaz
Journal:  Skull Base       Date:  2007-07

6.  Rapamycin-loaded nanoparticles for inhibition of neointimal hyperplasia in experimental vein grafts.

Authors:  Junjie Zou; Xiwei Zhang; Hongyu Yang; Yi Zhu; Hao Ma; Shui Wang
Journal:  J Cardiothorac Surg       Date:  2011-05-12       Impact factor: 1.637

7.  Overlapped Stenting for Treatment of an Extracranial Carotid Artery Aneurysm.

Authors:  Kiyoshi Tsuji; Norihito Fukawa; Nobuhiro Nakagawa; Tomonari Yabuuchi; Naoki Nakano; Amami Kato
Journal:  NMC Case Rep J       Date:  2015-06-26
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.