Literature DB >> 11286852

A comparison of dose distributions of proton and photon beams in stereotactic conformal radiotherapy of brain lesions.

B G Baumert1, A J Lomax, V Miltchev, J B Davis.   

Abstract

PURPOSE: Micromultileaf collimators (mMLC) have recently been introduced to conform photon beams in stereotactic irradiation of brain lesions. Proton beams and stereotactic conformal radiotherapy (SCRT) can be used to tailor the dose to nonspherical targets, as most tumors of the brain are irregularly shaped. Comparative planning of brain lesions using either proton or stereotactically guided photon beams was done to assess the institution's clinically available modality for three-dimensional conformal radiotherapy. METHODS AND MATERIALS: For the photon treatment, multiple stereotactically guided uniform intensity beams from a linear accelerator were used, each conformed to a projection of the planning target volume (PTV) by a mMLC. Proton beams were delivered from an isocentrically mounted gantry, using the spot-scanning technique and energy modulation. Seven patients were scanned in a stereotactic frame; target volumes and organs at risk (OAR) were delineated with the help of MR images. Four different lesions were selected: (1) concave, (2) ellipsoid isolated, (3) superficial and close to an organ at risk, and (4) irregular complex. Dose distributions in the PTV and critical structures were calculated using three-dimensional treatment-planning systems, followed by both a quantitative (by dose--volume histogram and conformity index) and qualitative (visual inspection) assessment of the plans.
RESULTS: A high degree of conformation was achieved with a mMLC and stereotactic uniform intensity beams with comparable conformity indices to protons for 5 out of 7 plans, especially for superficial or spherical lesions. In the cases studied, the conformity index was better for protons than for photons for complex or concave lesions, or when the PTV was in the neighborhood of critical structures.
CONCLUSION: The results for the cases studied, show that for simple geometries or for superficial lesions, there is no advantage in using protons. However, for complex PTV shapes, or when the PTV is in the vicinity of critical structures, protons seem to be potentially better than the fixed-field photon technique.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11286852     DOI: 10.1016/s0360-3016(00)01422-x

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  9 in total

Review 1.  Stereotactic radiosurgery for pituitary adenomas: a review of the literature.

Authors:  Edward R Laws; Jason P Sheehan; Jonas M Sheehan; Jay Jagnathan; John A Jane; Rod Oskouian
Journal:  J Neurooncol       Date:  2004 Aug-Sep       Impact factor: 4.130

Review 2.  Do we have enough evidence to implement particle therapy as standard treatment in lung cancer? A systematic literature review.

Authors:  Madelon Pijls-Johannesma; Janneke P C Grutters; Frank Verhaegen; Philippe Lambin; Dirk De Ruysscher
Journal:  Oncologist       Date:  2010-01-12

3.  Comparison of intensity modulated radiotherapy (IMRT) with intensity modulated particle therapy (IMPT) using fixed beams or an ion gantry for the treatment of patients with skull base meningiomas.

Authors:  Katsura Kosaki; Swantje Ecker; Daniel Habermehl; Stefan Rieken; Oliver Jäkel; Klaus Herfarth; Jürgen Debus; Stephanie E Combs
Journal:  Radiat Oncol       Date:  2012-03-22       Impact factor: 3.481

Review 4.  Radiation therapy planning with photons and protons for early and advanced breast cancer: an overview.

Authors:  Damien C Weber; Carmen Ares; Antony J Lomax; John M Kurtz
Journal:  Radiat Oncol       Date:  2006-07-20       Impact factor: 3.481

5.  Predictive Risk of Radiation Induced Cerebral Necrosis in Pediatric Brain Cancer Patients after VMAT Versus Proton Therapy.

Authors:  Derek Freund; Rui Zhang; Mary Sanders; Wayne Newhauser
Journal:  Cancers (Basel)       Date:  2015-04-10       Impact factor: 6.639

6.  Spontaneous Resolution of Radiotherapy-induced Craniopharyngioma Cyst.

Authors:  Mario Teo; Fiona Cowie; Paul Fivey; Jerome St George
Journal:  Cureus       Date:  2015-05-28

7.  Malignant bone tumors (other than Ewing's): clinical practice guidelines for diagnosis, treatment and follow-up by Spanish Group for Research on Sarcomas (GEIS).

Authors:  Andrés Redondo; Silvia Bagué; Daniel Bernabeu; Eduardo Ortiz-Cruz; Claudia Valverde; Rosa Alvarez; Javier Martinez-Trufero; Jose A Lopez-Martin; Raquel Correa; Josefina Cruz; Antonio Lopez-Pousa; Aurelio Santos; Xavier García Del Muro; Javier Martin-Broto
Journal:  Cancer Chemother Pharmacol       Date:  2017-10-16       Impact factor: 3.333

8.  The ROCOCO performance scoring system translates dosimetric differences into clinically relevant endpoints: Comparing IMPT to VMAT in an example pilocytic astrocytoma dataset.

Authors:  Lieke In 't Ven; Erik Roelofs; Macarena Cubillos Mesías; Inge Compter; Yvonne L B Klaver; Robert Jan Smeenk; Geert O Janssens; Johannes H A M Kaanders; Raquel Davila Fajardo; Foppe Oldenburger; Dirk de Ruysscher; Esther G C Troost; Daniëlle B P Eekers
Journal:  Clin Transl Radiat Oncol       Date:  2021-02-22

9.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.