Literature DB >> 11286340

Development of immunosensors for the analysis of 1-naphthol in organic media.

J Penalva1, R Puchades, A Maquieira, S Gee, B D Hammock.   

Abstract

Immunosensor systems have been developed for the rapid determination of 1-naphthol. In this work, the comparison of performance of immunosensors working in aqueous and organic media was done. Direct, indirect and capture formats were studied. Immunoreagents were immobilized on controlled pore glass (CPG), hidroxysuccinimide agarose gel or on azlactone Protein A/G supports. The Protein A/G-based sensor showed the best performance. In aqueous media, a LOD of 16.2 microg l(-1) and a DR of 33.7-586.6 microg l(-1) were achieved employing Tween 20 at a concentration ranging from 0.01 to 0.05% v/v. Maximum sensitivity was reached with 0.025% of surfactant. Binary mixtures of methanol or acetonitrile with aqueous buffer and ternary mixtures of methanol/isopropanol or ethyl acetate/methanol with the same buffer were studied as organic media. The mixture 50% MeOH-50% 20 mM sodium phosphate, pH 8, with 0.05% (v/v) Tween 20 resulted to be the best. A detection limit of 12.0 microg l(-1) and a dynamic range of 53.6-17,756.0 microg l(-1) were reached. The recycling of Protein A/G-based sensor working in this media was about 300 assays. Preconcentration factors around 250 were achieved using methanol as extracting solvent. It has been demonstrated that the technique can be successful in carrying out the analysis of low solubility in water analytes, such as 1-naphthol. The sensors developed can use higher concentrations of organic solvent (up to 50% methanol) compared to ELISA. On the other hand, the advantage of preconcentration can also be taken for the use of the same procedure as recommended for standard sample treatments.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11286340     DOI: 10.1016/s0956-5663(00)00059-2

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Regioselective 1,3-dipolar cycloaddition of phenanthrolinium N-ylides to substituted arylidene oxazolones.

Authors:  Yaşar Dürüst; Akın Sağırlı; Frank R Fronczek
Journal:  Mol Divers       Date:  2011-03-22       Impact factor: 2.943

2.  Single-step cycle pulse operation of the label-free electrochemiluminescence immunosensor based on branched polypyrrole for carcinoembryonic antigen detection.

Authors:  Wenjuan Zhu; Qi Wang; Hongmin Ma; Xiaohui Lv; Dan Wu; Xu Sun; Bin Du; Qin Wei
Journal:  Sci Rep       Date:  2016-04-19       Impact factor: 4.379

3.  Solid-Phase Spectrophotometric Analysis of 1-Naphthol Using Silica Functionalized with m-Diazophenylarsonic Acid.

Authors:  Nataliya Zaitseva; Sergei Alekseev; Vladimir Zaitsev; Viktoria Raks
Journal:  Nanoscale Res Lett       Date:  2016-03-15       Impact factor: 4.703

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.