Literature DB >> 11284763

Normative measurements of Korean orbital structures revealed by computerized tomography.

J S Lee1, D W Lim, S H Lee, B S Oum, H J Kim, H J Lee.   

Abstract

PURPOSE: The purposes of this study were to establish criteria for the diameters of normal extraocular muscles, the width of the optic nerve, and the globe position as revealed by CT, and to investigate the effects of age and sex on these parameters in the Korean population. SUBJECTS AND METHODS: Diameters of extraocular muscles (medial, lateral, superior complex, and inferior rectus), distance from the interzygomatic line to the posterior margin of the globe, width of the optic nerve-sheath complex, and length of the interzygomatic line were calculated for 214 patients on axial and direct coronal CT images, and the effects of age and sex were analyzed.
RESULTS: Normal range for the diameters as given by mean+/-2SDs of extraocular muscles were medial rectus, 2.2--5.4 mm; lateral rectus, 2.1--4.9 mm; inferior rectus, 2.5--5.7 mm; and superior complex group, 2.6--6.4 mm. The mean optic nerve-sheath complex was 4.1 mm and the values ranged from 2.9 mm to 5.3 mm. The mean length of the interzygomatic line was 103.8 mm. The normal posterior position of the globe as here designed was 11.2 mm behind the interzygomatic line (range, 6.4--15.3 mm). All parameters under study were a little larger in males than females. Statistically, however, there was no significant difference between males' and females' results, nor between the various age groups (p>0.05).
CONCLUSION: Our CT results may help clinical ophthalmologists to accurately assess enlargement of the extraocular muscles and the optic nerve as well as aiding in the evaluation of exophthalmos.

Entities:  

Mesh:

Year:  2001        PMID: 11284763     DOI: 10.1034/j.1600-0420.2001.079002197.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  10 in total

1.  Orbital positron emission tomography/computed tomography (PET/CT) imaging findings in Graves ophthalmopathy.

Authors:  Leonardo García-Rojas; Gloria Adame-Ocampo; Guillermo Mendoza-Vázquez; Erick Alexánderson; José Luis Tovilla-Canales
Journal:  BMC Res Notes       Date:  2013-09-04

2.  A new MRI method for the quantitative evaluation of extraocular muscle size in thyroid ophthalmopathy.

Authors:  K Aydin; K Güven; S Sencer; A Cikim; N Gül; O Minareci
Journal:  Neuroradiology       Date:  2003-02-19       Impact factor: 2.804

3.  Normative measurements of inferior oblique muscle thickness in Japanese by magnetic resonance imaging using a new technique.

Authors:  Maria Suzanne Sabundayo; Hirohiko Kakizaki; Yasuhiro Takahashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-01-19       Impact factor: 3.117

4.  Anatomical analysis of intraorbital structures regarding sinus surgery using multiplanar reconstruction of computed tomography scans.

Authors:  Se Hwan Hwang; Chan Soon Park; Jin Hee Cho; Soo Whan Kim; Byung Guk Kim; Jun Myung Kang
Journal:  Clin Exp Otorhinolaryngol       Date:  2013-03-08       Impact factor: 3.372

5.  Inferior oblique muscle thickness in Asians.

Authors:  Yasuhiro Takahashi; Hirohiko Kakizaki; Takashi Nakano; Ken Asamoto; Masayoshi Iwaki
Journal:  Clin Ophthalmol       Date:  2008-06

6.  Optic nerve sheath diameter threshold by ocular ultrasonography for detection of increased intracranial pressure in Korean adult patients with brain lesions.

Authors:  Si Un Lee; Jin Pyeong Jeon; Hannah Lee; Jung Ho Han; Mingu Seo; Hyoung Soo Byoun; Won-Sang Cho; Ho Geol Ryu; Hyun-Seung Kang; Jeong Eun Kim; Heung Cheol Kim; Kyung-Sool Jang
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

7.  Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers.

Authors:  Dong Hwan Kim; Jin-Sun Jun; Ryul Kim
Journal:  Sci Rep       Date:  2017-11-21       Impact factor: 4.379

8.  Computed tomography imaging-based normative orbital measurement in Indian population.

Authors:  Vivek Gupta; Anuj Prabhakar; Mukesh Yadav; Niranjan Khandelwal
Journal:  Indian J Ophthalmol       Date:  2019-05       Impact factor: 1.848

9.  Normative measurements of the superior oblique and inferior oblique muscles by magnetic resonance imaging.

Authors:  Khizar Rana; Valerie Juniat; Aaron Rayan; Sandy Patel; Dinesh Selva
Journal:  Surg Radiol Anat       Date:  2022-03-08       Impact factor: 1.246

10.  Relations between age, weight, refractive error and eye shape by computerized tomography in children.

Authors:  Ha Tae Song; Young Jun Kim; Soo Jung Lee; Yeon Sung Moon
Journal:  Korean J Ophthalmol       Date:  2007-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.