Literature DB >> 11283994

Steady-state preparation for spoiled gradient echo imaging.

R F Busse1, S J Riederer.   

Abstract

While spoiled gradient echo sequences provide a rapid means of acquiring T(1)-weighted images, it is often desirable that the magnetization be in the steady state to avoid artifacts. For some applications, this requires many "dummy" repetitions of the pulse sequence prior to data collection, delaying image acquisition. A method is presented in which a saturation pulse, followed by a prescribed recovery period, places longitudinal magnetization levels of all materials near steady state, ready for data acquisition much sooner than when employing only dummy repetitions to achieve steady state. Effects of transverse coherences are studied using configuration theory. The method is shown to be effective in both phantom studies and in vivo applications, including real-time imaging, multiphase cardiac imaging, and triggered contrast-enhanced angiography. Magn Reson Med 45:653-661, 2001. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11283994     DOI: 10.1002/mrm.1088

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

Review 1.  Stem cell therapy: MRI guidance and monitoring.

Authors:  Dara L Kraitchman; Wesley D Gilson; Christine H Lorenz
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

2.  Hybrid T2 - and T1 -weighted radial acquisition for free-breathing abdominal examination.

Authors:  Thomas Benkert; John P Mugler; David S Rigie; Daniel K Sodickson; Hersh Chandarana; Kai Tobias Block
Journal:  Magn Reson Med       Date:  2018-04-15       Impact factor: 4.668

3.  Reduction of flow artifacts by using partial saturation in RF-spoiled gradient-echo imaging.

Authors:  Misung Han; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-11       Impact factor: 4.668

4.  Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence.

Authors:  Liyong Chen; Ganesh Adluru; Matthias C Schabel; Chris J McGann; Edward V R Dibella
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

5.  Wireless MR tracking of interventional devices using phase-field dithering and projection reconstruction.

Authors:  Martin A Rube; Andrew B Holbrook; Benjamin F Cox; J Graeme Houston; Andreas Melzer
Journal:  Magn Reson Imaging       Date:  2014-03-17       Impact factor: 2.546

Review 6.  MR fluoroscopy in vascular and cardiac interventions (review).

Authors:  Maythem Saeed; Steve W Hetts; Joey English; Mark Wilson
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

7.  Hexagonal gradient scheme with RF spoiling improves spoiling performance for high-flip-angle fast gradient echo imaging.

Authors:  Aaron T Hess; Matthew D Robson
Journal:  Magn Reson Med       Date:  2016-04-01       Impact factor: 4.668

  7 in total