RATIONALE AND
OBJECTIVES: To evaluate a new technique with mechanical administration of aerosolized gadolinium (Gd)-DTPA for MR visualization of lung ventilation.
METHODS: Ten experimental procedures were performed in six domestic pigs. Gd-DTPA was aerosolized by a small-particle generator. The intubated animals were mechanically aerosolized with the nebulized contrast agent and studied on a 1.5-T MR imager. Respiratory gated T1-weighted turbo spin-echo images were obtained before, during, and after contrast administration. Pulmonary signal intensity (SI) changes were calculated for corresponding regions of both lungs. Homogeneity of aerosol distribution was graded independently by two radiologists.
RESULTS: To achieve a comparable SI increase as attained in previous trials that used manual aerosol ventilation, a ventilation period of 20 minutes (formerly 30 minutes) was sufficient. Mean SI changes of 116% were observed after that duration. Contrast delivery was rated evenly distributed in all cases by the reviewers.
CONCLUSIONS: The feasibility of applying Gd-DTPA as a contrast agent to demonstrate pulmonary ventilation in large animals has been described before. The results of this refined technique substantiate the potential of Gd-based ventilation MR imaging by improving aerosol distribution and shortening the nebulization duration in the healthy lung.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11283422     DOI: 10.1097/00004424-200104000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  (3)He-MRI in follow-up of lung transplant recipients.

Authors:  Klaus Kurt Gast; Julia Zaporozhan; Sebastian Ley; Alexander Biedermann; Frank Knitz; Balthasar Eberle; Joerg Schmiedeskamp; Claus-Peter Heussel; Eckhard Mayer; Wolfgang Günter Schreiber; Manfred Thelen; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2003-10-16       Impact factor: 5.315

2.  Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

Authors:  Jessica M Oakes; Miriam Scadeng; Ellen C Breen; G Kim Prisk; Chantal Darquenne
Journal:  Ann Biomed Eng       Date:  2013-01-25       Impact factor: 3.934

Review 3.  [Functional 3He-MRI of the lungs].

Authors:  K K Gast; U Wolf
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

4.  Nebulized liposomal gadobenate dimeglumine contrast formulation for magnetic resonance imaging of larynx and trachea.

Authors:  Xiaohui Wei; Huawei Wu; Qing Lu; Jianrong Xu; Yuhong Xu
Journal:  Int J Nanomedicine       Date:  2011-12-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.