Literature DB >> 11275666

Caries detection methods: can they aid decision making for invasive sealant treatment?

A C Pereira1, E H Verdonschot, M C Huysmans.   

Abstract

The decision to place sealants is a difficult one, and it has been suggested that in a low risk population it may be efficient to wait until caries is detected in the fissure. An invasive sealant technique with fissure preparation may then be indicated. The diagnostic method used in the indication of such a procedure should accurately detect both dentine caries and sound fissures: high sensitivity for dentine caries (at D3 threshold) with high specificity for enamel caries (at D1 threshold). The aims of this study were to assess the diagnostic performance of selected diagnostic methods at normal cut-offs for traditional dentine caries detection and at reduced cut-offs in relation to the desired performance mentioned above, and to assess whether fissure opening allows for accurate visual detection of dentinal caries. Data were obtained from 230 occlusal sites of 101 extracted human molar teeth. Diagnostic methods used on the entire sample were: visual inspection, electrical conductance measurements and laser fluorescence measurements. The sample was then divided into two groups. Group 1 was subjected to visual inspection after application of a dye. Group 2 was subjected to visual inspection after fissure opening only, and after subsequent dye application. Validation was performed by histological investigation. The results with cut-offs normally used in dentine caries detection were roughly in accordance with the literature, except for laser fluorescence. The sensitivity of visual inspection for dentinal caries (D3) was 17% before and 70% after fissure opening. Using reduced cut-offs, a 100% sensitivity (D3) was achieved with 2 methods, but this also resulted in 63 or 87% false positive diagnoses of sound surfaces. Visual inspection and electrical methods both showed a moderate to high sensitivity (D3) with a higher than 50% specificity (D1). It was concluded that visual inspection and electrical methods at reduced cut-offs may aid the indication of invasive sealant treatment. The visual detection of dentinal caries is substantially increased, but not perfect after fissure opening.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11275666     DOI: 10.1159/000047437

Source DB:  PubMed          Journal:  Caries Res        ISSN: 0008-6568            Impact factor:   4.056


  8 in total

1.  Diagnostic accuracy of different imaging modalities in detection of proximal caries.

Authors:  B Senel; K Kamburoglu; O Uçok; S P Yüksel; T Ozen; H Avsever
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

2.  The influence of zero value subtraction on the performance of a new laser fluorescence device for approximal caries detection.

Authors:  Jonas Almeida Rodrigues; Jonas de Almeida Rodrigues; Isabel Hug; Adrian Lussi
Journal:  Lasers Med Sci       Date:  2008-02-29       Impact factor: 3.161

3.  The effect of pit and fissure sealants on the detection of occlusal caries in vitro.

Authors:  D J Manton; L B Messer
Journal:  Eur Arch Paediatr Dent       Date:  2007-03

4.  In vivo evaluation of laser fluorescence performance using different cut-off limits for occlusal caries detection.

Authors:  Michele Baffi Diniz; Jonas Almeida Rodrigues; Jonas de Almeida Rodrigues; Andréia Bolzan de Paula; Rita de Cássia Loiola Cordeiro
Journal:  Lasers Med Sci       Date:  2008-03-01       Impact factor: 3.161

5.  Current status of dental caries diagnosis using cone beam computed tomography.

Authors:  Young-Seok Park; Jin-Soo Ahn; Ho-Beom Kwon; Seung-Pyo Lee
Journal:  Imaging Sci Dent       Date:  2011-06-23

6.  Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries.

Authors:  Mehrdad Abdinian; Rahman Nazeri; Marzieh Ghaiour
Journal:  J Dent (Tehran)       Date:  2017-07

7.  Effect of Filtration and Slice Thickness of Cone-Beam Computed Tomography Images on Occlusal Caries Detection: An Ex Vivo Study.

Authors:  Mehrdad Abdinian; Marzieh Ghaiour
Journal:  J Dent (Tehran)       Date:  2018-09

8.  Reliability analysis of two methods for measuring active enamel demineralization: An in vitro study.

Authors:  Camila Nassur; Luciana Pomarico; Lucianne Cople Maia
Journal:  Eur J Dent       Date:  2013-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.