Literature DB >> 11275031

Urinary interleukin-8 with asymptomatic bacteriuria in pregnancy.

S D Shelton1, K A Boggess, K Kirvan, F Sedor, W N Herbert.   

Abstract

OBJECTIVE: To evaluate urinary interleukin-8 (IL-8), an inflammatory cytokine, as a screening method for detecting asymptomatic bacteriuria in pregnancy.
METHODS: Clean-catch urine samples from 200 pregnant women undergoing screening for asymptomatic bacteriuria were evaluated by urine culture, urine dipstick analysis, and measurement of IL-8. Interleukin-8 levels were measured by a chemiluminescent immunoassay (Immulite IL-8, Diagnostic Products Corp., Los Angeles, CA), and a receiver operating characteristic curve was used to determine the optimal cutoff point. Asymptomatic bacteriuria was defined as at least 100,000 colony-forming units of a single organism per mL. Dipstick testing included nitrite assessment as positive or negative and leukocyte esterase as negative, trace, 1+, 2+, or 3+. Dipstick testing was considered positive if nitrite was positive or leukocyte esterase was trace or greater. Sensitivities, specificities, positive and negative predictive values were determined for urinary leukocyte esterase and nitrite and compared with those of IL-8. chi(2) and Mann-Whitney U tests were used for statistical analyses.
RESULTS: Twenty women were identified with asymptomatic bacteriuria by urine culture. The median urinary IL-8 levels for women with and without asymptomatic bacteriuria were 356 pg/mL and 125 pg/mL, respectively (P <.01, Mann-Whitney U test). Using an optimal cutoff point of 264 pg/mL, IL-8 had a sensitivity, specificity, positive and negative predictive value of 70%, 67%, 19%, and 95% for predicting asymptomatic bacteriuria. Urine dipstick analysis with either a positive leukocyte esterase or nitrite had a sensitivity, specificity, positive and negative predictive value of 45%, 62%, 12%, and 91%, respectively, for detecting asymptomatic bacteriuria. The differences between these testing methods were not statistically significant.
CONCLUSION: Urinary interleukin-8 is not an acceptable screening method for asymptomatic bacteriuria in pregnancy because it fails to detect 30% of women with this condition.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11275031     DOI: 10.1016/s0029-7844(00)01226-6

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  3 in total

1.  Can the Griess Nitrite Test and a Urinary Pus Cell Count of ≥5 Cells Per Micro Litre of Urine in Pregnant Women be Used for the Screening or the Early Detection of Urinary Tract Infections in Rural India?

Authors:  Sushama S Thakre; Supriya S Dhakne; Subhash B Thakre; Amol D Thakre; Suresh M Ughade; Priya Kale
Journal:  J Clin Diagn Res       Date:  2012-11

Review 2.  A best practice position statement on pregnancy in chronic kidney disease: the Italian Study Group on Kidney and Pregnancy.

Authors:  Gianfranca Cabiddu; Santina Castellino; Giuseppe Gernone; Domenico Santoro; Gabriella Moroni; Michele Giannattasio; Gina Gregorini; Franca Giacchino; Rossella Attini; Valentina Loi; Monica Limardo; Linda Gammaro; Tullia Todros; Giorgina Barbara Piccoli
Journal:  J Nephrol       Date:  2016-03-17       Impact factor: 3.902

3.  Clinical Validation of Innovative Optical-Sensor-Based, Low-Cost, Rapid Diagnostic Test to Reduce Antimicrobial Resistance.

Authors:  Suman Kapur; Manish Gehani; Nagamani Kammili; Pankaj Bhardwaj; Vijayalakshmi Nag; Sudha M Devara; Shashwat Sharad
Journal:  J Clin Med       Date:  2019-12-01       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.