BACKGROUND: Bence Jones proteins or monoclonal immunoglobulin kappa and lambda free light chains (FLCs) are important markers for identifying and monitoring many patients with B-cell tumors. Automated immunoassays that measure FLCs in urine and serum have considerable clinical potential. METHODS: Sheep antibodies, specific for FLCs, were prepared by immunization with pure kappa and lambda molecules and then adsorbed extensively against whole immunoglobulins. The antibodies were conjugated onto latex particles and used to assay kappa and lambda FLCs on the Beckman IMMAGE protein analyzer. RESULTS: The unconjugated antibodies showed minimal cross-reactivity with intact immunoglobulins or other proteins. With latex-conjugated antibodies, kappa and lambda FLCs could be measured in normal sera and most normal urine samples. Patients with multiple myeloma had increased concentrations of the relevant serum FLC, whereas both FLCs were increased in the sera of patients with systemic lupus erythematosus. CONCLUSIONS: We developed sensitive, automated immunoassays for kappa and lambda FLC measurements in serum and urine that should facilitate the assessment of patients with light chain abnormalities.
BACKGROUND: Bence Jones proteins or monoclonal immunoglobulin kappa and lambda free light chains (FLCs) are important markers for identifying and monitoring many patients with B-cell tumors. Automated immunoassays that measure FLCs in urine and serum have considerable clinical potential. METHODS:Sheep antibodies, specific for FLCs, were prepared by immunization with pure kappa and lambda molecules and then adsorbed extensively against whole immunoglobulins. The antibodies were conjugated onto latex particles and used to assay kappa and lambda FLCs on the Beckman IMMAGE protein analyzer. RESULTS: The unconjugated antibodies showed minimal cross-reactivity with intact immunoglobulins or other proteins. With latex-conjugated antibodies, kappa and lambda FLCs could be measured in normal sera and most normal urine samples. Patients with multiple myeloma had increased concentrations of the relevant serum FLC, whereas both FLCs were increased in the sera of patients with systemic lupus erythematosus. CONCLUSIONS: We developed sensitive, automated immunoassays for kappa and lambda FLC measurements in serum and urine that should facilitate the assessment of patients with light chain abnormalities.
Authors: Colin A Hutchison; Paul Cockwell; Stephanie Stringer; Arthur Bradwell; Mark Cook; Morie A Gertz; Angela Dispenzieri; Jeffrey L Winters; Shaji Kumar; S Vincent Rajkumar; Robert A Kyle; Nelson Leung Journal: J Am Soc Nephrol Date: 2011-04-21 Impact factor: 10.121
Authors: Colin A Hutchison; Vecihi Batuman; Judith Behrens; Frank Bridoux; Christophe Sirac; Angela Dispenzieri; Guillermo A Herrera; Helen Lachmann; Paul W Sanders Journal: Nat Rev Nephrol Date: 2011-11-01 Impact factor: 28.314
Authors: Sherry Mori; Brooke S Crawford; Julianna Vf Roddy; Gary Phillips; Pat Elder; Craig C Hofmeister; Yvonne Efebera; Don M Benson Journal: Hematol Oncol Date: 2011-10-26 Impact factor: 5.271
Authors: Shaji Kumar; Angela Dispenzieri; Jerry A Katzmann; Dirk R Larson; Colin L Colby; Martha Q Lacy; Suzanne R Hayman; Francis K Buadi; Nelson Leung; Steve R Zeldenrust; Marina Ramirez-Alvarado; Raynell J Clark; Robert A Kyle; S Vincent Rajkumar; Morie A Gertz Journal: Blood Date: 2010-08-26 Impact factor: 22.113
Authors: Eric A Engels; Barbara Savoldo; Ruth M Pfeiffer; Rene Costello; Adriana Zingone; Helen E Heslop; Ola Landgren Journal: Transplantation Date: 2013-02-15 Impact factor: 4.939