Literature DB >> 11270523

Low-intensity pulsed ultrasound initiates bone healing in rat nonunion fracture model.

S Takikawa1, N Matsui, T Kokubu, M Tsunoda, H Fujioka, K Mizuno, Y Azuma.   

Abstract

Low-intensity pulsed ultrasound exposure has been shown clinically to shorten the fracture repair process and to induce healing of nonunions in humans, but its mechanism of action remains unclear. In this study we investigated the effect and mechanism of low-intensity pulsed ultrasound on nonunion fracture healing in rat tibias. A consistently reproducible nonunion was produced in rat tibias by muscle interposition without osteotomy. This model was produced by creating a closed tibial fracture with only the distal end of the tibialis anterior muscle interposed into the fracture site. One limb was noninvasively exposed to low-intensity pulsed ultrasound (a 200-millisecond burst of sine waves of 1.5 MHz, repeating at 1.0 kHz) for 20 minutes daily. The incident intensity was approximately 30 mW/cm2. Rats were killed at intervals between 2 and 6 weeks. The events were assessed by radiographs, microfocus X-ray computed tomograms, and histologic examination. After 6 weeks of exposure, 7 of 14 nonunion fractures showed healing on radiologic assessment. The results of three-dimensional microfocus X-ray computed tomographic reconstruction and histologic examination also supported this finding. On the other hand, all control tibias remained in a state of nonunion during the same period. These results indicate that low-intensity pulsed ultrasound promotes healing in the rat nonunion fracture model.

Entities:  

Mesh:

Year:  2001        PMID: 11270523     DOI: 10.7863/jum.2001.20.3.197

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  26 in total

1.  Ultrasound treatment of nonunion of the hook of the hamate in sports activities.

Authors:  Hiroyuki Fujioka; Juichi Tanaka; Shinichi Yoshiya; Masaya Tsunoda; Kenji Fujita; Nobuzo Matsui; Takeshi Makino; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-09-20       Impact factor: 4.342

2.  Experimental study on low intensity ultrasound and tissue engineering to repair segmental bone defects.

Authors:  Fagang Ye; Changsuo Xia; Renyun Xia
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2006

3.  Osteogenic differentiation of adipose-derived stem cells prompted by low-intensity pulsed ultrasound.

Authors:  Y Yue; X Yang; X Wei; J Chen; N Fu; Y Fu; K Ba; G Li; Y Yao; C Liang; J Zhang; X Cai; M Wang
Journal:  Cell Prolif       Date:  2013-06       Impact factor: 6.831

Review 4.  Overview of non-invasive factors (low level laser and low intensity pulsed ultrasound) accelerating tooth movement during orthodontic treatment.

Authors:  Mohammed Mahmood Jawad; Adam Husein; Mohammad Khursheed Alam; Rozita Hassan; Rumaizi Shaari
Journal:  Lasers Med Sci       Date:  2012-09-18       Impact factor: 3.161

5.  Low intensity pulsed ultrasound in the treatment of long bone nonunions: Evaluation of cytokine expression as a tool for objectifying nonunion therapy.

Authors:  Arash Moghaddam; Timur Mert Yildirim; Fabian Westhauser; Wolfgang Danner; Tyler Swing; Thomas Bruckner; Bahram Biglari
Journal:  J Orthop       Date:  2016-07-02

6.  Low-Intensity Amplitude Modulated Ultrasound Increases Osteoblastic Mineralization.

Authors:  Sardar M Zia Uddin; Jiqi Cheng; Wei Lin; Yi-Xian Qin
Journal:  Cell Mol Bioeng       Date:  2010-12-14       Impact factor: 2.321

7.  Low-Intensity Pulsed Ultrasound Stimulation Enhances Heat-Shock Protein 90 and Mineralized Nodule Formation in Mouse Calvaria-Derived Osteoblasts.

Authors:  Munemitsu Miyasaka; Hidemi Nakata; Jia Hao; You-Kyoung Kim; Shohei Kasugai; Shinji Kuroda
Journal:  Tissue Eng Part A       Date:  2015-11-19       Impact factor: 3.845

8.  Inhibition of myostatin signal pathway may be involved in low-intensity pulsed ultrasound promoting bone healing.

Authors:  Lijun Sun; Shuxin Sun; Xinjuan Zhao; Jing Zhang; Jianzhong Guo; Liang Tang; Dean Ta
Journal:  J Med Ultrason (2001)       Date:  2019-08-03       Impact factor: 1.314

9.  Combined use of low-intensity pulsed ultrasound and rhBMP-2 to enhance bone formation in a rat model of critical size defect.

Authors:  Siddhesh R Angle; Kotaro Sena; Dale R Sumner; Walter W Virkus; Amarjit S Virdi
Journal:  J Orthop Trauma       Date:  2014-10       Impact factor: 2.512

10.  Low-intensity pulsed ultrasound: Nonunions.

Authors:  Bernadetta G Dijkman; Sheila Sprague; Mohit Bhandari
Journal:  Indian J Orthop       Date:  2009-04       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.