Literature DB >> 112640

Gamma-ray spectrometry of humans at the University of Utah.

R D Lloyd, C W Mays, D H Taysum.   

Abstract

A human total-body counter was designed and built with two 20 X 10 cm NaI (Tl) crystals suspended over an "isoresponse surface" upon which the subject reclines. This surface is curved from head to knee and from left to right, so that a gamma-ray emitting object is detected with equal efficiency when placed anywhere upon it. The positioner and detectors are housed in a low background enclosure constructed of steel 31 cm thick with a graded inner lining of lead + cadmium + copper. Calibration of the system was accomplished by administering trace amounts of various radionuclides to 48 human subjects of various sizes, ranging in age from 4--80 years. Counting rates per retained muCi at 0.53, 0.66, 1.53, and 2.75 MeV (83Rb, 137Cs, 42K, and 24Na) were determined as a function of body size and were compared with counting rates per muCi of corresponding emitters centered in a polyethylene cylinder of radius 10.3 cm. Limits of detection, corresponding to three times the standard deviation of a 50 min background, were 170 nCi 90Sr (via Bremsstrahlung X-rays), 0.78 nCi 131I, 0.48 nCi 83Rb, 0.52 nCi 137 Cs, 4.9 nCi 40K (or 5.8 g of natural potassium) and 1.7 nCi 222Rn.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 112640     DOI: 10.1007/bf01323223

Source DB:  PubMed          Journal:  Radiat Environ Biophys        ISSN: 0301-634X            Impact factor:   1.925


  9 in total

1.  AN IMPROVED WHOLE-BODY COUNTING GEOMETRY WITH A SINGLE NAI (TL) DETECTOR (8 X 4 INCHES).

Authors:  A S CHHABRA
Journal:  Radiology       Date:  1964-05       Impact factor: 11.105

2.  Metabolism of 83 Rb and 137 Cs in persons with muscle disease.

Authors:  R D Lloyd; C W Mays; S S McFarland; W S Zundel; F H Tyler
Journal:  Radiat Res       Date:  1973-06       Impact factor: 2.841

3.  Meson dosimetry for the natural environment.

Authors:  R Gold
Journal:  Radiat Res       Date:  1973-12       Impact factor: 2.841

4.  Self-attenuation and geometry in single-crystal whole-body spectrometry. Application to total potassium measurement in man.

Authors:  G Joyet; A Baudraz
Journal:  Experientia       Date:  1968-09-15

5.  [Gamma autoabsorption and geometry of measurement with a sole crystal in spectrometry of whole body counting].

Authors:  G Joyet
Journal:  Rev Med Liege       Date:  1968-10

6.  NaI (T1) detector efficiency calculations for distributed sources in a human phantom.

Authors:  A Andrási; G Kötél
Journal:  Int J Appl Radiat Isot       Date:  1975-08

7.  Estimation of the total hydrogen content of the human body.

Authors:  J Rundo; L J Bunce
Journal:  Nature       Date:  1966-06-04       Impact factor: 49.962

8.  Intercomparison of the reliability of body cesium-137 measurements on human beings.

Authors:  C J Maletskos; P N Dean; S A Lough; C E Miller
Journal:  Health Phys       Date:  1967-12       Impact factor: 1.316

9.  90Sr + 90Y bremsstrahlung efficiency predicted for humans.

Authors:  R D Lloyd; C W Mays; D R Atherton; G N Taylor
Journal:  Radiat Environ Biophys       Date:  1976-10-07       Impact factor: 1.925

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.