Literature DB >> 11262696

Ophthalmodynamometry: a reliable method for measuring intracranial pressure.

M Motschmann1, C Müller, J Kuchenbecker, S Walter, K Schmitz, M Schütze, W Behrens-Baumann, R Firsching.   

Abstract

Under physiological conditions, the pressure in the central retinal vein is equal to or higher than the intracranial pressure (ICP) because the cerebrospinal fluid (CSF) passes the sheath of the optic nerve before draining into the cavernous sinus. The optic nerve sheath is where the ICP affects the retinal venous pressure. Ophthalmodynamometry (ODM) is a useful method for determining the central retinal artery pressure. While papilledema and a lack of venous pulsations are commonly used as a vague indication of the ICP, ODM may be advantageous for determining the pressure in the central retinal vein. Until now, however, the venous pressure has never been compared with the intracranial pressure. In the present study, the pressure in the central retinal vein was recorded in 31 patients while the ICP was simultaneously being recorded for various reasons. The results demonstrate a linear correlation (r = 0.968) between the pressure in the central retinal vein and the ICP. This correlation is of great practical value since until now, reliable intracranial pressure monitoring has only been possible by invasive means, by placing a probe either in the brain parenchyma or the ventricle. Ophthalmodynamometry is useful for momentary assessment of the ICP, can easily be repeated, and may be used whenever an elevated ICP is suspected in hydrocephalus, brain tumors and after head injury. However, it is not suitable for continuous ICP monitoring.

Entities:  

Mesh:

Year:  2001        PMID: 11262696     DOI: 10.1076/stra.9.1.13.711

Source DB:  PubMed          Journal:  Strabismus        ISSN: 0927-3972


  12 in total

1.  Ophthalmodynamometric measurement of central retinal vein pressure as surrogate of intracranial pressure in idiopathic intracranial hypertension.

Authors:  Jost B Jonas; Katrin Pfeil; Anastasios Chatzikonstantinou; Florian Rensch
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-02-15       Impact factor: 3.117

2.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

3.  Detection and characterization of tree shrew retinal venous pulsations: An animal model to study human retinal venous pulsations.

Authors:  Michael Dattilo; A Thomas Read; Brian C Samuels; C Ross Ethier
Journal:  Exp Eye Res       Date:  2019-06-06       Impact factor: 3.467

4.  Modeling a potential SANS countermeasure by experimental manipulation of the translaminar pressure difference in mice.

Authors:  Guofu Shen; Schuyler S Link; Xiaofeng Tao; Benjamin J Frankfort
Journal:  NPJ Microgravity       Date:  2020-07-31       Impact factor: 4.415

Review 5.  Noninvasive assessment of cerebrospinal fluid pressure.

Authors:  Beau B Bruce
Journal:  J Neuroophthalmol       Date:  2014-09       Impact factor: 3.042

6.  Linear interactions between intraocular, intracranial pressure, and retinal vascular pulse amplitude in the fourier domain.

Authors:  Anmar Abdul-Rahman; William Morgan; Ying Jo Khoo; Christopher Lind; Allan Kermode; William Carroll; Dao-Yi Yu
Journal:  PLoS One       Date:  2022-06-28       Impact factor: 3.752

7.  Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest.

Authors:  Henry W Querfurth; Philip Lieberman; Steve Arms; Steve Mundell; Michael Bennett; Craig van Horne
Journal:  BMC Neurol       Date:  2010-11-01       Impact factor: 2.474

8.  Noninvasive intracranial pressure estimation by orbital subarachnoid space measurement: the Beijing Intracranial and Intraocular Pressure (iCOP) study.

Authors:  Xiaobin Xie; Xiaojun Zhang; Jidi Fu; Huaizhou Wang; Jost B Jonas; Xiaoxia Peng; Guohong Tian; Junfang Xian; Robert Ritch; Lei Li; Zefeng Kang; Shoukang Zhang; Diya Yang; Ningli Wang
Journal:  Crit Care       Date:  2013-07-24       Impact factor: 9.097

9.  Modeling a potential SANS countermeasure by experimental manipulation of the translaminar pressure difference in mice.

Authors:  Guofu Shen; Schuyler S Link; Xiaofeng Tao; Benjamin J Frankfort
Journal:  NPJ Microgravity       Date:  2020-07-31       Impact factor: 4.415

10.  Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure.

Authors:  Keihan Golshani; Mehdi Ebrahim Zadeh; Ziba Farajzadegan; Fariborz Khorvash
Journal:  Emerg (Tehran)       Date:  2015
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.