Literature DB >> 11262531

Can the proximal isovelocity surface area method calculate stenotic mitral valve area in patients with associated moderate to severe aortic regurgitation? Analysis using low aliasing velocity of 10% of the peak transmitral velocity.

H Ikawa1, E Enya, Y Hirano, H Uehara, Y Ozasa, S Yamada, K Ishikawa.   

Abstract

To assess the ability of the proximal isovelocity surface area (PISA) method to accurately measure the stenotic mitral valve area (MVA), and to assess whether aortic regurgitation (AR) affects the calculation, we compared the accuracy of the PISA method and the pressure half-time (PHT) method for determining MVA in patients with and without associated AR by using two-dimensional echocardiographic planimetry as a standard. The study population consisted of 45 patients with mitral stenosis. Seventeen of the 45 patients had associated moderate-to-severe AR. The PISA method was performed using low aliasing velocity (AV) of 10% of the peak transmitral velocity, which provided the most accurate estimation of MVA when compared with planimetry. The maximal radius r of the PISA was measured from the orifice to blue-red aliasing interface. Using the PISA method, MVA was calculated as (2pir(2)) x theta / 180 x AV/Vmax, where theta was the inflow angle formed by mitral leaflets, AV was the aliasing velocity (cm/sec), and Vmax was the peak transmitral velocity (cm/sec). MVA by the PISA method correlated well with planimetry both in patients with AR (r = 0.90, P < 0.001, SEE = 0.17 cm(2)) and without AR (r = 0.92, P < 0.001, SEE = 0.16 cm(2)). However, MVA by the PHT method did not correlate as well with planimetry (r = 0.57, P < 0.05, SEE = 0.37 cm(2)) in patients with associated AR, and the PHT method produced a significant overestimation (24%) of MVA obtained by planimetry in these patients. We conclude that the PISA method allows accurate estimation of MVA and is not influenced by AR.

Entities:  

Mesh:

Year:  2001        PMID: 11262531     DOI: 10.1046/j.1540-8175.2001.00089.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Simplifying proximal isovelocity surface area as an assessment method of mitral valve area in patients with rheumatic mitral stenosis by fixing aliasing velocity and mitral valve angle.

Authors:  Alaa Mabrouk Salem Omar; Mohammed Ahmed Abdel-Rahman; Hidekazu Tanaka; Osama Rifaie
Journal:  J Saudi Heart Assoc       Date:  2012-12-04

2.  The impact of cardiac rhythm on the mitral valve area and gradient in patients with mitral stenosis.

Authors:  Hasan Arı; Selma Arı; Alper Karakuş; Sencer Camcı; Kübra Doğanay; Ahmet Tütüncü; Mehmet Melek; Tahsin Bozat
Journal:  Anatol J Cardiol       Date:  2017-05-24       Impact factor: 1.596

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.