Literature DB >> 11261343

Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults.

E A Mallen1, J S Wolffsohn, B Gilmartin, S Tsujimura.   

Abstract

A clinical evaluation of the Shin-Nippon SRW-5000 (Japan), a newly released commercial autorefractor, was undertaken to assess its repeatability and validity compared to subjective refraction. Measurements of refractive error were performed on 200 eyes of 100 subjects (aged 24.4 +/- 8.0 years) subjectively (non-cycloplegic) by one optometrist and objectively with the SRW-5000 autorefractor by a second. Repeatability was assessed by examining the differences between the seven autorefractor readings taken from each eye and by re-measuring the objective prescription of 50 eyes at a subsequent session. Although the SRW-5000 read slightly more plus than subjective refraction (mean spherical equivalent +0.16 +/- 0.44 D), it was found to be highly valid (accurate) compared to subjective refraction and repeatable over the prescription range of +6.50 to -15.00 D examined. The Shin-Nippon SRW-5000 autorefractor is therefore a valuable complement to subjective refraction and as it offers the advantage of a binocular open field-of-view, has a great potential benefit for accommodation research studies.

Mesh:

Year:  2001        PMID: 11261343

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  32 in total

1.  Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function.

Authors:  O A Hunt; J S Wolffsohn; B Gilmartin
Journal:  Br J Ophthalmol       Date:  2003-12       Impact factor: 4.638

2.  Effect of unilateral forced nostril breathing on tonic accommodation and intraocular pressure.

Authors:  Jennifer C Chen; Brian Brown; Katrina L Schmid
Journal:  Clin Auton Res       Date:  2004-12       Impact factor: 4.435

3.  Influence of accommodative lag upon the far-gradient measurement of accommodative convergence to accommodation ratio in strabismic patients.

Authors:  Manabu Miyata; Satoshi Hasebe; Hiroshi Ohtsuki
Journal:  Jpn J Ophthalmol       Date:  2006 Sep-Oct       Impact factor: 2.447

4.  Subjective and objective performance of the Lenstec KH-3500 "accommodative" intraocular lens.

Authors:  J S Wolffsohn; S A Naroo; N K Motwani; S Shah; O A Hunt; S Mantry; M Sira; I A Cunliffe; M T Benson
Journal:  Br J Ophthalmol       Date:  2006-03-10       Impact factor: 4.638

5.  Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor.

Authors:  Meritxell Vilaseca; Montserrat Arjona; Jaume Pujol; Elvira Peris; Vanessa Martínez
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

Review 6.  Restoration of accommodation: surgical options for correction of presbyopia.

Authors:  Adrian Glasser
Journal:  Clin Exp Optom       Date:  2008-05       Impact factor: 2.742

7.  Central and peripheral autorefraction repeatability in normal eyes.

Authors:  Kelly E Moore; David A Berntsen
Journal:  Optom Vis Sci       Date:  2014-09       Impact factor: 1.973

8.  Aberrometry Repeatability and Agreement with Autorefraction.

Authors:  Mylan T Nguyen; David A Berntsen
Journal:  Optom Vis Sci       Date:  2017-09       Impact factor: 1.973

9.  Tonic accommodation predicts closed-loop accommodation responses.

Authors:  Chunming Liu; Stefanie A Drew; Eric Borsting; Amy Escobar; Lawrence Stark; Christopher Chase
Journal:  Vision Res       Date:  2016-11-01       Impact factor: 1.886

10.  Receding and disparity cues aid relaxation of accommodation.

Authors:  Anna M Horwood; Patricia M Riddell
Journal:  Optom Vis Sci       Date:  2009-11       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.