Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket.

M Zhang1, C Roberts.   

Abstract

Interface pressures and shear stresses between a below-knee residual limb and prosthetic socket predicted using finite element analyses were compared with experimental measurements. A three-dimensional nonlinear finite element model, based on actual residual geometry and incorporating PTB socket rectification and interfacial friction/slip conditions, was developed to predict the stress distribution. A system for measuring pressures and bi-axial shear stresses was used to measure the stresses in the PTB socket of a trans-tibial amputee. The FE-predicted results indicated that the peak pressure of 226 kPa occurred at the patellar tendon area and the peak shear stress of 50 kPa at the anterolateral tibia area. Quantitatively, FE-predicted pressures were 11%, on average, lower than those measured by triaxial transducers placed at all the measurement sites. Because friction/slip conditions between the residual limb and socket liner were taken into consideration by using interface elements in the FE model, the directions and magnitudes of shear stresses match well between the FE prediction and clinical measurements. The results suggest that the nonlinear mechanical properties of soft tissues and dynamic effects during gait should be addressed in future work.

Entities:  

Mesh:

Year:  2000        PMID: 11259929     DOI: 10.1016/s1350-4533(00)00079-5

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

2.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

Review 3.  The use of fiber Bragg grating sensors in biomechanics and rehabilitation applications: the state-of-the-art and ongoing research topics.

Authors:  Ebrahim Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2012-09-25       Impact factor: 3.576

4.  Development of an air pneumatic suspension system for transtibial prostheses.

Authors:  Gholamhossein Pirouzi; Noor Azuan Abu Osman; Azim Ataollahi Oshkour; Sadeeq Ali; Hossein Gholizadeh; Wan A B Wan Abas
Journal:  Sensors (Basel)       Date:  2014-09-09       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.