Intercomparison of five PM10 monitoring devices and the implications for exposure measurement in epidemiological research.

M R Heal1, I J Beverland, M McCabe, W Hepburn, R M Agius.   

Abstract

Five different instruments for the determination of the mass concentration of PM10 in air were compared side-by-side for up to 33 days in an undisturbed indoor environment: a tripod mounted BGI Inc. PQ100 gravimetric sampler with a US EPA certified Graseby Andersen PM10 inlet; an Airmetrics Minivol static gravimetric sampler; a Casella cyclone gravimetric personal sampler; an Institute of Occupational Medicine gravimetric PM10 personal sampler; and two TSI Inc. Dustrak real-time optical scattering personal samplers. For 24 h sampling of ambient PM10 concentrations around 10 microg m(-3), the estimated measurement uncertainty for the two gravimetric personal samplers was larger (approximately +/- 20%) compared with estimated measurement uncertainty for the PQ100/Graseby Andersen sampler (< +/- 5%). Measurement uncertainty for the Dustraks was lower (approximately +/- 15% on average) but calibration of the optical response against a reference PM10 method is essential since the Dustraks systematically over-read PM10 determined gravimetrically by a factor approximately 2.2. However, once calibrated, the Dustrak devices demonstrated excellent functionality in terms of ease of portability and real-time data acquisition. Estimated measurement uncertainty for PM10 concentrations determined with the Minivol were +/- 5%. The Minivol data correlated well with PQ100/Graseby Andersen data (r= 0.97, n = 18) but were, on average, 23% greater. The reason for the systematic discrepancy could not be traced. Intercomparison experiments such as these are essential for assessing measurement error and revealing systematic bias. Application of two Dustraks demonstrated the spatial and temporal variability of exposure to PM10 in different walking and transport microenvironments in the city of Edinburgh, UK. For example, very large exposures to PM10 were identified for the lower deck of a double-decker tour bus compared with the open upper deck of the same vehicle. The variability observed emphasises the need to determine truly personal exposure profiles of PM10 for quantifying exposure response relationships for epidemiological studies.

Mesh:

Year:  2000        PMID: 11254050     DOI: 10.1039/b002741n

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  4 in total

1.  Correction factor for continuous monitoring of wood smoke fine particulate matter.

Authors:  Marcy L McNamara; Curtis W Noonan; Tony J Ward
Journal:  Aerosol Air Qual Res       Date:  2011-06-01       Impact factor: 3.063

2.  Re-construction of the shut-down PM10 monitoring stations for the reliable assessment of PM10 in Berlin using fuzzy modelling and data transformation.

Authors:  Hamid Taheri Shahraiyni; Sahar Sodoudi; Andreas Kerschbaumer; Ulrich Cubasch
Journal:  Environ Monit Assess       Date:  2017-02-28       Impact factor: 2.513

3.  Size-Selective Sampling Performance of Six Low-Volume "Total" Suspended Particulate (TSP) Inlets.

Authors:  Robert W Vanderpool; Jonathan D Krug; Surender Kaushik; Jerome Gilberry; Andrew Dart; Carlton L Witherspoon
Journal:  Aerosol Sci Technol       Date:  2018       Impact factor: 2.908

4.  The Spatio-Temporal Distribution of Particulate Matter during Natural Dust Episodes at an Urban Scale.

Authors:  Helena Krasnov; Itai Kloog; Michael Friger; Itzhak Katra
Journal:  PLoS One       Date:  2016-08-11       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.