Engineering considerations in the design of an ankle joint.

G E Kempson, M A Freeman, M A Tuke.   

Abstract

A prothesis has been designed to replace the articulating surfaces of the human ankle joint. The prothesis is in two parts, each forming a segment of a right circular cylinder with a single axis of rotation. The concave tibial component is manufactured from ultra-high molecular weight polyethylene and the talar component is manufactured from medical grade stainless steel. It is likely, however, that the talar component will be commercially manufactured from cobalt chrome alloy (Vitallium or Vinertia). The two components are secured to the cancellous bone by polymethylmethacrylate bone cement and laboratory tests have indicated that the bond should be strong enough to withstand the loads encountered at the ankle joint in vivo. The tests have also shown that the stability and strength of the ankle are not seriously reduced by implantation of the prosthesis. Laboratory wear tests and clinical experience over the last two years encourage optimism over the long term performance of the prothesis.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1125359

Source DB:  PubMed          Journal:  Biomed Eng        ISSN: 0006-2898


  7 in total

1.  Dynamic simulation of the natural and replaced human ankle joint.

Authors:  A Leardini; D Moschella
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

2.  The Scandinavian Total Ankle Replacement and the ideal biomechanical requirements of ankle replacements.

Authors:  Shibby Robati; Alan Salih; Koushik Ghosh; Parthiban Vinayakam
Journal:  J Orthop       Date:  2015-10-31

3.  Ankle joint synoviography in rheumatoid arthritis.

Authors:  G Hug; A S Dixon
Journal:  Ann Rheum Dis       Date:  1977-12       Impact factor: 19.103

4.  Total ankle replacement compatible with ligament function produces mobility, good clinical scores, and low complication rates: an early clinical assessment.

Authors:  Sandro Giannini; Matteo Romagnoli; John J O'Connor; Francesco Malerba; Alberto Leardini
Journal:  Clin Orthop Relat Res       Date:  2010-06-18       Impact factor: 4.176

5.  The production and biology of polyethylene wear debris.

Authors:  P A Revell; B Weightman; M A Freeman; B V Roberts
Journal:  Arch Orthop Trauma Surg       Date:  1978-05-30

6.  Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study.

Authors:  Chien-Chung Kuo; Hsuan-Lun Lu; Tung-Wu Lu; Cheng-Chung Lin; Alberto Leardini; Mei-Ying Kuo; Horng-Chaung Hsu
Journal:  Biomed Eng Online       Date:  2013-12-20       Impact factor: 2.819

7.  Biomechanics of the natural, arthritic, and replaced human ankle joint.

Authors:  Alberto Leardini; John J O'Connor; Sandro Giannini
Journal:  J Foot Ankle Res       Date:  2014-02-06       Impact factor: 2.303