Literature DB >> 11253012

Evaluation of VOC measurments in the EXPOLIS study. Air Pollution Exposure Distributions within Adult Urban Urban Populations in Europe.

J Jurvelin1, R Edwards, K Saarela, J Laine-Ylijoki, M De Bortoli, L Oglesby, K Schläpfer, L Georgoulis, E Tischerova, O Hänninen, M Jantunen.   

Abstract

Personal exposures and microenvironment concentrations of 30 target VOCs were measured for 401 participants living in five European cities as a part of the EXPOLIS (Air Pollution Exposure Distributions within Adult Urban Populations in Europe) study. Measurements in Basel used an active charcoal (Carbotech) adsorbent as opposed to the Tenax TA used in the other study centres. In addition, within each centre, personal and microenvironment VOC sampling required different sampling pumps and, because of different sampling durations, different sampling flow rates. Thus, careful testing of the sampling and analysis procedures was required to ensure accuracy and comparability of collected data. Monitor comparison tests using Tenax TA showed a mean VOC concentration ratio of 0.95 between the personal and microenvironment monitors. The LODs for the target VOCs using Tenax TA ranged from 0.7 to 5.2 microg m(-3). The LODs for the 14 target compounds quantifiable using Carbotech ranged from 0.9 to 3.2 microg m(-3). Tenax TA field blanks showed no remarkable contamination with the target VOCs, except benzaldehyde, a known artefact with this adsorbent. Thus, the diffusion barrier system used prevented contamination of Tenax TA samples by passive diffusion during non-sampling periods. Duplicate and parallel evaluations of the Tenax TA and Carbotech showed an average difference of < 17% in VOC concentrations within the sampling methods, but a systematic difference between the methods (Tenax TA: Carbotech concentration ratio = 1.18-2.36). These field evaluations and quality assurance tests showed that interpretation and comparison of the results in any VOC monitoring exercise should be done on a compound by compound basis. It is also apparent that carefully planned and realised QA and QC (QA/QC) procedures are needed in multi-centre studies, where a common sampling method and laboratory analysis technique are not used, to strengthen and simplify the interpretation of observed VOC levels between participating centres.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11253012     DOI: 10.1039/b007600g

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  6 in total

Review 1.  Benzene exposure: an overview of monitoring methods and their findings.

Authors:  Clifford P Weisel
Journal:  Chem Biol Interact       Date:  2010-01-06       Impact factor: 5.192

2.  Determining the levels of volatile organic pollutants in urban air using a gas chromatography-mass spectrometry method.

Authors:  Simona Nicoara; Loris Tonidandel; Pietro Traldi; Jonathan Watson; Geraint Morgan; Ovidiu Popa
Journal:  J Environ Public Health       Date:  2010-02-03

3.  Common household chemicals and the allergy risks in pre-school age children.

Authors:  Hyunok Choi; Norbert Schmidbauer; Jan Sundell; Mikael Hasselgren; John Spengler; Carl-Gustaf Bornehag
Journal:  PLoS One       Date:  2010-10-18       Impact factor: 3.240

4.  Indoor air VOC concentrations in suburban and rural New Jersey.

Authors:  Clifford P Weisel; Shahnaz Alimokhtari; Paul F Sanders
Journal:  Environ Sci Technol       Date:  2008-11-15       Impact factor: 9.028

5.  An analysis of factors that influence personal exposure to toluene and xylene in residents of Athens, Greece.

Authors:  Evangelos C Alexopoulos; Christos Chatzis; Athena Linos
Journal:  BMC Public Health       Date:  2006-02-28       Impact factor: 3.295

Review 6.  Airborne environmental injuries and human health.

Authors:  Andrea T Borchers; Christopher Chang; Carl L Keen; M Eric Gershwin
Journal:  Clin Rev Allergy Immunol       Date:  2006-08       Impact factor: 8.667

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.