Influence of environmental parameters on the accuracy of nitrogen dioxide passive diffusion tubes for ambient measurement.

C Kirby1, M Fox, J Waterhouse, T Drye.   

Abstract

Two studies at three sites in the UK provided confirmation that systematic positive bias in NO2 diffusion tube measurement occurred because of changes to "within-tube" chemistry, rather than eddy diffusion at the mouth of the tube. In the first study in Cambridge, UK, sampler overestimation for 1 and 2 week exposures was compared to corresponding time-averaged monitor measurements (NO-NO2-NOx, O3) and weather variables. Noninearity between sampler and monitor NO2 measurements was interpreted in terms of spatial and temporal variations in relative and absolute availability of NO, NO2 and O3 at the site. A maximum overestimation occurred for an exposure mean NO2/NOx approximately 0.5. The separate contributions of reduced NO2 photolysis and eddy diffusion were compared in Study II using samplers of two materials, acrylic and quartz, and of different lengths (40, 55, 71 and 120 mm) at three sites: Norwich background, Cambridge intermediate, London kerbside. For compared sites, NO2 measured by acrylic samplers was significantly higher than for equivalent quartz samplers. For quartz samplers [NO2]mean was only just above the monitor at Norwich and London; sampler/monitor NO2 = 1.04 (P = 0.59) and 1.01(P = 0.76), respectively. For acrylic samplers the order of [NO2]mean was 40 mm > 120 mm > 71 mm > or = 55 mm. Excepting 40 mm samplers, this accords with a chemical bias where co-diffusing NO and 03 molecules in longer tubes have more time to react to form excess NO2. Bias in 40 mm samplers is discussed. Eddy diffusion is negligible for standard samplers because [NO2]mean was equivalent for 55 mm and 71 mm acrylic samplers and close to monitor NO2 for 71 mm quartz tubes. Both studies showed that sampler accuracy was dependent on location. Significantly, overestimation was greatest (approximately 3-4 ppb) where the NO2 annual mean was approximately 20 ppb, close to the UK and EU air quality standard of 21 ppb.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11253011     DOI: 10.1039/b007839p

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  3 in total

1.  Field study of diffusion collection rate coefficients of a NO2 passive sampler in a Mediterranean coastal area.

Authors:  Juana Maria Delgado-Saborit; Vicente Esteve-Cano
Journal:  Environ Monit Assess       Date:  2006-06-02       Impact factor: 2.513

2.  Use of passive diffusion tubes to monitor air pollutants.

Authors:  David G Nash; David Leith
Journal:  J Air Waste Manag Assoc       Date:  2010-02       Impact factor: 2.235

Review 3.  Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: a review.

Authors:  Chang Ho Yu; Maria T Morandi; Clifford P Weisel
Journal:  J Expo Sci Environ Epidemiol       Date:  2008-04-30       Impact factor: 5.563

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.