S Proux1, L Hkirijareon, C Ngamngonkiri, S McConnell, F Nosten.
Abstract
We compared the performance of Paracheck-Pf, a new and cheap rapid malaria test, with ICT-Pf/PvR and microscopy in two malaria surveys in Thai villages on the Thai-Burmese border. The specificity, sensitivity, predictive positive and negative values of the Paracheck-PfR and ICT-PfR tests were calculated taking microscopy results as the gold standard. The 294 ICT-Pf/Pv tests resulted in two invalid (no control line) and 11 doubtful results. Both the ICT-Pf/PvR and Paracheck-PfR tests reliably detected P. falciparum infections. However, Paracheck-PfR failed to detect three P. falciparum cases and likewise, ICT-Pf/PvR failed to detect the same three cases and an additional four cases. These seven cases were detected by microscopy and had a parasitaemia under 150 parasites/microl. At a cost of c. US $1.00, the Paracheck-PfR test, based on the detection of the P. falciparum specific HRP-2 protein, is a reliable, easy to use and affordable tool for the diagnosis of P. falciparum malaria.Entities:
Mesh:
Substances:
Year: 2001 PMID: 11251904 DOI: 10.1046/j.1365-3156.2001.00694.x
Source DB: PubMed Journal: Trop Med Int Health ISSN: 1360-2276 Impact factor: 2.622