Literature DB >> 1124886

Comparison of maximal mid-expiratory flow, flow volume curves, and nitrogen closing volumes in patients with mild airway obstruction.

R T Abboud, J W Morton.   

Abstract

Maximal mid-expiratory flow (MMEF), maximal expiratory flow volume (MEFV) curves obtained with a wedge spirometer, and nitrogen closing volumes were determined in 38 patients with mild airway obstruction. Seventeen patients had asthma in remission and 21 had bronchitis. In all of them the forced expiratory volume in one second was within the normal range. Results were compared with predicted data in the literature and with a group of normal control subjects. In the patients with asthma, compared to predicted flow rates, MMEF was abnormal in 5, MEFV curves were abnormal in at least 8; closing volume was abnormally increased in only one patient, and an abnormal slope of the alveolar plateau was present in 4 additional patients. In the patients with bronchitis, compared to predicted flow rates, -MEF was reduced in 5, MEFV curves were abnormal in at least 7; increased closing volumes were present in 6, and the slope of the alveolar plateau was abnormal in 3 other patients. When flow rates were compared with those of normal control subjects, MMEF was about as frequently abnormal as MEFV curves, suggesting that the discrepancy between abnormal MMEF AND MEFV curves was due to variability of the predicted data. The results indicated that flow rates can be abnormal in subjects with normal closing volumes and a normal slope of the alveolar plateau, and that MEFV curves can be more sensitive than closing volume in detecting abnormalities in patients with mild airway obstruction. The results suggested that the use of both MEFV curves and the closing volume test for screening would defect functional abnormalities more frequently than either test alone.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1124886     DOI: 10.1164/arrd.1975.111.4.405

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  4 in total

1.  Intrasubject variability of maximal expiratory flow volume curve.

Authors:  G M Cochrane; F Prieto; T J Clark
Journal:  Thorax       Date:  1977-04       Impact factor: 9.139

2.  Investigation of intrinsic disturbance wave near the end of expiration.

Authors:  S C Zhang
Journal:  Acta Acad Med Wuhan       Date:  1985

3.  Small airway disease in rheumatoid arthritis.

Authors:  J H Lee; G Y Suh; K Y Lee; C G Yoo; Y W Kim; S K Han; Y S Shim; K Y Kim; Y C Han; S D Lee
Journal:  Korean J Intern Med       Date:  1992-07       Impact factor: 2.884

4.  Maximal mid-expiratory flow is a surrogate marker of lung clearance index for assessment of adults with bronchiectasis.

Authors:  Wei-Jie Guan; Jing-Jing Yuan; Yong-Hua Gao; Hui-Min Li; Jin-Ping Zheng; Rong-Chang Chen; Nan-Shan Zhong
Journal:  Sci Rep       Date:  2016-06-24       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.