Literature DB >> 11247933

Pulmonary perfusion in supine and prone positions: an electron-beam computed tomography study.

A T Jones1, D M Hansell, T W Evans.   

Abstract

Acute respiratory distress syndrome is characterized by alterations in the ventilation-perfusion ratio. Present techniques for studying regional pulmonary perfusion are difficult to apply in the critically ill. Electron-beam computed tomography was used to study the effects of prone positioning on regional pulmonary perfusion in six healthy subjects. Contrast-enhanced sections were obtained sequentially in the supine, prone, and (original) supine positions at full inspiration. Regions of interest were placed along the nondependent to dependent axis and relative perfusion calculated. When corrected for the redistribution of lung parenchyma, a gravitational gradient of pulmonary perfusion existed in both supine and prone positions. The distribution of perfusion between the supine or prone positions did not differ, but data analysis using smaller regions of interest demonstrated marked heterogeneity of perfusion between anatomically adjacent regions of lung. The distribution of lung parenchyma was more uniform in the prone position. Gravity was estimated to be responsible for 22-34% of perfusion heterogeneity in the supine and 27-41% in the prone positions. These data support the hypothesis that factors other than gravity may be at least as important in determining the distribution of pulmonary perfusion in humans. The influence of nongravitational factors may not be detectable if techniques that sample large tissue volumes are employed.

Entities:  

Mesh:

Year:  2001        PMID: 11247933     DOI: 10.1152/jappl.2001.90.4.1342

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  24 in total

Review 1.  The pulmonary physician in critical care. 8: Ventilatory management of ALI/ARDS.

Authors:  J J Cordingley; B F Keogh
Journal:  Thorax       Date:  2002-08       Impact factor: 9.139

2.  Physical therapy management of ventilated patients with acute respiratory distress syndrome or severe acute lung injury.

Authors:  Frank Chung; Dan Mueller
Journal:  Physiother Can       Date:  2011-04-13       Impact factor: 1.037

3.  Vertical gradients in regional lung density and perfusion in the supine human lung: the Slinky effect.

Authors:  Susan R Hopkins; A Cortney Henderson; David L Levin; Kei Yamada; Tatsuya Arai; Richard B Buxton; G Kim Prisk
Journal:  J Appl Physiol (1985)       Date:  2007-03-29

4.  Pulmonary perfusion in the prone and supine postures in the normal human lung.

Authors:  G Kim Prisk; Kei Yamada; A Cortney Henderson; Tatsuya J Arai; David L Levin; Richard B Buxton; Susan R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2007-06-14

5.  The effect of supine exercise on the distribution of regional pulmonary blood flow measured using proton MRI.

Authors:  E T Hall; R C Sá; S Holverda; T J Arai; D J Dubowitz; R J Theilmann; G K Prisk; S R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2013-12-19

Review 6.  Towards a virtual lung: multi-scale, multi-physics modelling of the pulmonary system.

Authors:  K S Burrowes; A J Swan; N J Warren; M H Tawhai
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2008-09-28       Impact factor: 4.226

7.  Posture-dependent human 3He lung imaging in an open-access MRI system: initial results.

Authors:  Leo L Tsai; Ross W Mair; Chih-Hao Li; Matthew S Rosen; Samuel Patz; Ronald L Walsworth
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

Review 8.  Modelling pulmonary blood flow.

Authors:  Merryn H Tawhai; Kelly S Burrowes
Journal:  Respir Physiol Neurobiol       Date:  2008-03-16       Impact factor: 1.931

Review 9.  Determinants of regional ventilation and blood flow in the lung.

Authors:  Robb W Glenny
Journal:  Intensive Care Med       Date:  2009-11       Impact factor: 17.440

10.  Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging.

Authors:  Inéz Frerichs; José Hinz; Peter Herrmann; Gerald Weisser; Günter Hahn; Michael Quintel; Gerhard Hellige
Journal:  IEEE Trans Med Imaging       Date:  2002-06       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.