Literature DB >> 11241843

Random mutagenesis-PCR to introduce alterations into defined DNA sequences for validation of SNP and mutation detection methods.

M L Nickerson1, M B Warren, B Zbar, L S Schmidt.   

Abstract

Sensitive and high throughput techniques are required for the detection of DNA sequence variants such as single nucleotide polymorphisms (SNPs) and mutations. One problem, common to all methods of SNP and mutation detection, is that experimental conditions required for detection of DNA sequence variants depend on the specific DNA sequence to be analyzed. Although algorithms and other calculations have been developed to predict the experimental conditions required to detect DNA sequence variation in a specific DNA sequence, these algorithms do not always provide reliable information and experimental conditions for SNP and mutation detection must be devised empirically. Determination of experimental conditions for detection of DNA sequence variation is difficult when samples containing only wild type sequence are available. When patient derived positive controls are used, increasingly there are valid concerns about commercial ownership and patient privacy. This report presents a rapid and efficient method, employing random mutagenesis-PCR (RM-PCR) using low fidelity DNA polymerase, to randomly introduce single and multiple base substitutions and deletions into DNA sequences of interest. Clones with sequence changes were used to validate denaturing HPLC (DHPLC) algorithm predictions, optimize conditions for mutation detection in exon 15 of the tyrosine kinase domain of the MET proto-oncogene, and to confirm the association between specific DNA sequence changes and unique DHPLC chromatographic profiles (signatures). Finally, DNA from 33 papillary renal carcinoma (PRC) patients was screened for mutations in exon 15 of MET using "validated" DHPLC conditions as a proof of principle application of RM-PCR. Use of RM-PCR for DHPLC and other SNP/mutation detection methods is discussed along with challenges associated with detecting sequence alterations in mixed tumor/normal tissue, pooled samples, and from regions of the genome that have been amplified during tumorigenesis or duplicated during evolution. Hum Mutat 17:210-219, 2001. Published 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11241843     DOI: 10.1002/humu.6

Source DB:  PubMed          Journal:  Hum Mutat        ISSN: 1059-7794            Impact factor:   4.878


  3 in total

1.  Temperature-modulated array high-performance liquid chromatography.

Authors:  A Premstaller; W Xiao; H Oberacher; M O'Keefe; D Stern; T Willis; C G Huber; P J Oefner
Journal:  Genome Res       Date:  2001-11       Impact factor: 9.043

2.  Pitfalls in the denaturing high-performance liquid chromatography analysis of mitochondrial DNA mutation.

Authors:  Kok Seong Lim; Robert K Naviaux; Scott Wong; Richard H Haas
Journal:  J Mol Diagn       Date:  2007-12-28       Impact factor: 5.568

3.  Improved identification of von Hippel-Lindau gene alterations in clear cell renal tumors.

Authors:  Michael L Nickerson; Erich Jaeger; Yangu Shi; Jeffrey A Durocher; Sunil Mahurkar; David Zaridze; Vsevolod Matveev; Vladimir Janout; Hellena Kollarova; Vladimir Bencko; Marie Navratilova; Neonilia Szeszenia-Dabrowska; Dana Mates; Anush Mukeria; Ivana Holcatova; Laura S Schmidt; Jorge R Toro; Sara Karami; Rayjean Hung; Gary F Gerard; W Marston Linehan; Maria Merino; Berton Zbar; Paolo Boffetta; Paul Brennan; Nathaniel Rothman; Wong-Ho Chow; Frederic M Waldman; Lee E Moore
Journal:  Clin Cancer Res       Date:  2008-08-01       Impact factor: 12.531

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.