Literature DB >> 11241818

A multi-scale method for automatic correction of intensity non-uniformity in MR images.

C Han1, T S Hatsukami, C Yuan.   

Abstract

In this paper, a novel multi-scale method for coil sensitivity profile correction is presented based on wavelet transform. A magnetic resonance (MR) image can be decomposed into two spaces by the wavelet transform: approximate space and residual space. The approximate templates in approximate space can be thought of as multi-scale sensitivity profiles of the surface coil for coil correction. When we choose a suitable filter for decomposition, one of the sensitivity profiles should be optimal among the multi-scale sensitivity profiles. The optimal sensitivity profile can be chosen automatically by an analysis of the contents of the two spaces. The multi-scale method does not rely on any data other than the image generated by the MR scanner. The experiment showed promising results based on one-dimensional simulation and images of phantom and human images.

Entities:  

Mesh:

Year:  2001        PMID: 11241818     DOI: 10.1002/jmri.1062

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  Restoration of MRI Data for Field Nonuniformities using High Order Neighborhood Statistics.

Authors:  Stathis Hadjidemetriou; Colin Studholme; Susanne Mueller; Michael Weiner; Norbert Schuff
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2007-03-05

2.  Restoration of MRI data for intensity non-uniformities using local high order intensity statistics.

Authors:  Stathis Hadjidemetriou; Colin Studholme; Susanne Mueller; Michael Weiner; Norbert Schuff
Journal:  Med Image Anal       Date:  2008-06-07       Impact factor: 8.545

3.  Segmentation priors from local image properties: without using bias field correction, location-based templates, or registration.

Authors:  Andrej Vovk; Robert W Cox; Janez Stare; Dusan Suput; Ziad S Saad
Journal:  Neuroimage       Date:  2010-12-10       Impact factor: 6.556

4.  An active contour model for the segmentation of images with intensity inhomogeneities and bias field estimation.

Authors:  Chencheng Huang; Li Zeng
Journal:  PLoS One       Date:  2015-04-02       Impact factor: 3.240

5.  Semi-automatic carotid intraplaque hemorrhage detection and quantification on Magnetization-Prepared Rapid Acquisition Gradient-Echo (MP-RAGE) with optimized threshold selection.

Authors:  Jin Liu; Niranjan Balu; Daniel S Hippe; Marina S Ferguson; Vanesa Martinez-Malo; J Kevin DeMarco; David C Zhu; Hideki Ota; Jie Sun; Dongxiang Xu; William S Kerwin; Thomas S Hatsukami; Chun Yuan
Journal:  J Cardiovasc Magn Reson       Date:  2016-07-16       Impact factor: 5.364

6.  Surface Coil Intensity Correction in Magnetic Resonance Imaging in Spinal Metastases.

Authors:  Hong Ren; Wei Lin; Xianjun Ding
Journal:  Open Med (Wars)       Date:  2017-05-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.