Literature DB >> 11241806

Myocardial flow reserve parametric map, assessed by first-pass MRI compartmental analysis at the chronic stage of infarction.

P Germain1, G Roul, J Baruthio, C Jahn, P M Coulbois, B Dumitresco, J L Dietemann, P Bareiss, A Constantinesco.   

Abstract

Regional myocardial flow and flow reserve (MFR) were assessed by compartmental analysis of Gd-enhanced MRI first-pass data in 7 patients with atypical chest pain, and in 15 patients with previous transmural myocardial infarction. The FE product (Flow x Extraction coefficient), derived from the modified Kety equation, was measured in regions corresponding to the Tetrofosmine-SPECT fixed defect and in remote normal regions. The FE product at rest and hyperemic FE product were similar in healed revascularized tissues (70.5 +/- 15.6 and 112.5 +/- 19.5 ml/mn/100 g, respectively) and in normal myocardium (76.2 +/- 18.3 and 142.2 +/- 33.0, respectively). In contrast, the FE index (48.8 +/- 15.2 and 60.7 +/- 18.0, respectively, P < 0.01 versus the two previous groups) and the MFR (1.27 +/- 0.20 vs. 1.91 +/- 0.29 in normal regions) were reduced in healed fibrotic tissues when the infarct-related artery remained occluded. Myocardial flow reserve maps allowed correct identification of regions corresponding to an occluded infarct-related artery.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11241806     DOI: 10.1002/jmri.1050

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  Estimation of coronary flow reserve: can SPECT compete with other modalities?

Authors:  G T Gullberg; E V Di Bella; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

2.  Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches.

Authors:  Giovanni Storto; Andrea Soricelli; Teresa Pellegrino; Mario Petretta; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

Review 3.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

4.  Measurement of coronary flow reserve by noninvasive cardiac imaging.

Authors:  Alberto Cuocolo; Mario Petretta; Andrea Soricelli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06       Impact factor: 9.236

Review 5.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

Review 6.  Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers.

Authors:  Mario Petretta; Andrea Soricelli; Giovanni Storto; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2008 May-Jun       Impact factor: 5.952

  6 in total