Literature DB >> 11241012

Measurement of left ventricular volumes by 3-dimensional echocardiography with tissue harmonic imaging: a comparison with magnetic resonance imaging.

W Y Kim1, P Søgaard, B O Kristensen, H Egeblad.   

Abstract

We hypothesized that tissue harmonic imaging (THI) in comparison with fundamental imaging (FI) would improve endocardial border detection, and therefore in combination with 3-dimensional echocardiography (3D echo), it would be a precise method for left ventricular (LV) volume measurement. Ten healthy subjects and 18 consecutive patients with dilated hearts underwent estimation of LV volumes by magnetic resonance imaging (MRI) and transthoracic 3D echo with THI and FI. In patients, the agreement between MRI and 3D echo was closer with THI in comparison with FI for assessment of LV volumes. Thus the mean +/- 2 SD of differences between MRI and 3D echo with THI versus FI, respectively, was -6.4 +/- 40.0 mL versus -17.4 +/- 57.6 mL (P <.01) for the end-diastolic volume (EDV), and 0.0 +/- 26.6 mL versus -8.1 +/- 35.6 mL (P <.01) for the end-systolic volume (ESV). In patients, THI in comparison with FI approximately halved observer variation on EDV and ESV. In healthy subjects, only ESV showed significantly reduced observer variation by THI. In conclusion, because THI demonstrated a clinically relevant reduction in observer variation and a closer agreement to the MRI technique in patients with dilated hearts, it should replace FI in LV volume measurements.

Entities:  

Mesh:

Year:  2001        PMID: 11241012     DOI: 10.1067/mje.2001.111479

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

1.  Assessment of left ventricular volume and function by integration of simplified 3D echocardiography, tissue harmonic imaging and automated extraction of endocardial borders.

Authors:  Donato Mele; Roberta Teoli; Corrado Cittanti; Giovanni Pasanisi; Gabriele Guardigli; Robert A Levine; Roberto Ferrari
Journal:  Int J Cardiovasc Imaging       Date:  2004-06       Impact factor: 2.357

Review 2.  Assessment of ventricular function and mass by cardiac magnetic resonance imaging.

Authors:  Khaled Alfakih; Scott Reid; Tim Jones; Mohan Sivananthan
Journal:  Eur Radiol       Date:  2004-07-17       Impact factor: 5.315

3.  Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes.

Authors:  J A van der Heide; H F J Mannaerts; L Yang; G T Sieswerda; C A Visser; O Kamp
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

Review 4.  Assessment of left ventricular function by three-dimensional echocardiography.

Authors:  Boudewijn J Krenning; Marco M Voormolen; Jos R T C Roelandt
Journal:  Cardiovasc Ultrasound       Date:  2003-09-08       Impact factor: 2.062

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.