Literature DB >> 11239692

Normalized pulse volume (NPV) derived photo-plethysmographically as a more valid measure of the finger vascular tone.

Y Sawada1, G Tanaka, K Yamakoshi.   

Abstract

Normalized pulse volume (NPV) was advocated as a more valid measure for the assessment of finger vascular tone. Based on the optical model in the finger tip expressed by Lambert--Beer's law, NPV is expressed as Delta I(a)/I. Here, Delta I(a) is the intensity of pulsatile component superimposed on the transmitted light (I). Theoretically, NPV seems to be superior to the conventional pulse volume (PV; corresponding to Delta I(a)). Firstly, NPV is in direct proportion to Delta V(a), which is the pulsatile component of the arterial blood volume, in a more exact manner. Relatedly, NPV can be processed as if it is an absolute value. Secondly, the sensitivity of NPV during stressful stimulations is expected to be higher. These expectations were supported experimentally using 13 male students. Firstly, the correlation between cutaneous vascular resistance in the finger tip (CVR) and NPV was higher than that between CVR and PV among all the subjects, although there was not much difference between these correlations within each subject. Secondly, NPV decreased much more than PV during mental stress. Some limitations of the present study were addressed, including the point that certain factors can violate the direct proportional relationship of NPV and PV to Delta V(a).

Mesh:

Year:  2001        PMID: 11239692     DOI: 10.1016/s0167-8760(00)00162-8

Source DB:  PubMed          Journal:  Int J Psychophysiol        ISSN: 0167-8760            Impact factor:   2.997


  9 in total

1.  Relationship between salivary Chromogranin-A and stress induced by simulated monotonous driving.

Authors:  Takehiro Yamakoshi; Sang-Bum Park; Won-Cheoul Jang; Kyungho Kim; Yasuhiro Yamakoshi; Hajime Hirose
Journal:  Med Biol Eng Comput       Date:  2009-02-05       Impact factor: 2.602

2.  Fish consumption and cardiovascular response during mental stress.

Authors:  Kenta Matsumura; Takehiro Yamakoshi; Hiroko Noguchi; Peter Rolfe; Yutaka Matsuoka
Journal:  BMC Res Notes       Date:  2012-06-13

3.  Cardiovascular hemodynamic effects of Red Bull® Energy Drink during prolonged, simulated, monotonous driving.

Authors:  Takehiro Yamakoshi; Kenta Matsumura; Shota Hanaki; Peter Rolfe
Journal:  Springerplus       Date:  2013-05-09

4.  The current and future status of the concealed information test for field use.

Authors:  Izumi Matsuda; Hiroshi Nittono; John J B Allen
Journal:  Front Psychol       Date:  2012-11-27

5.  iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

Authors:  Kenta Matsumura; Peter Rolfe; Jihyoung Lee; Takehiro Yamakoshi
Journal:  PLoS One       Date:  2014-03-11       Impact factor: 3.240

6.  A standardized validity assessment protocol for physiological signals from wearable technology: Methodological underpinnings and an application to the E4 biosensor.

Authors:  Hendrika G van Lier; Marcel E Pieterse; Ainara Garde; Marloes G Postel; Hein A de Haan; Miriam M R Vollenbroek-Hutten; Jan Maarten Schraagen; Matthijs L Noordzij
Journal:  Behav Res Methods       Date:  2020-04

7.  Cuffless blood pressure estimation based on haemodynamic principles: progress towards mobile healthcare.

Authors:  Takehiro Yamakoshi; Peter Rolfe; Ken-Ichi Yamakoshi
Journal:  PeerJ       Date:  2021-05-25       Impact factor: 2.984

8.  Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation towards Practical Non-Invasive Measurement of Blood Constituents.

Authors:  Takehiro Yamakoshi; Jihyoung Lee; Kenta Matsumura; Yasuhiro Yamakoshi; Peter Rolfe; Daiki Kiyohara; Ken-ichi Yamakoshi
Journal:  PLoS One       Date:  2015-12-04       Impact factor: 3.240

9.  Cuffless blood pressure estimation using only a smartphone.

Authors:  Kenta Matsumura; Peter Rolfe; Sogo Toda; Takehiro Yamakoshi
Journal:  Sci Rep       Date:  2018-05-08       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.