Literature DB >> 11238301

Simultaneous absolute quantification of target and control templates by real-time fluorescence reverse transcription-PCR using 4-(4'-dimethylaminophenylazo)benzoic acid as a dark quencher dye.

K A Kreuzer1, A Bohn, J Lupberger, J Solassol, P le Coutre, C A Schmidt.   

Abstract

BACKGROUND: Despite the many advantages of real-time fluorescence reverse transcription-PCR (RT-PCR) as a quantitative analytical tool, simultaneous quantification of target and reference templates within one reaction has not been reported. We developed such an assay with an internal reference template.
METHODS: For quantification of target and reference sequences, we used two fluorescent probes in one reaction vessel on an ABI PRISM 7700 SDS instrument. Fluorescent probes were labeled with either 6-carboxy-fluorescein or hexachloro-6-carboxy-fluorescein as reporter dye and 4-(4'-dimethylaminophenylazo)benzoic acid (DABCYL) as a dark quencher fluorophore. To test the sensitivity and specificity of this assay, serial dilutions of reference and target templates were analyzed in one PCR reaction. In the presence of 10 beta-actin molecules as control templates, 10(5) bcr/abl molecules were amplified, and 10(5) beta-actin molecules were amplified in the presence of 10 bcr/abl copies. We also performed single and duplex measurements on samples from five patients with documented Philadelphia chromosome-positive chronic myelogenous leukemia disease courses (72 samples) and three with minor bcr/abl+ acute myelogenous leukemias (26 samples).
RESULTS: For M-bcr/abl duplex RT-PCR, the correlation coefficient (r) for starting template amounts and threshold cycle values was 0.99; for m-bcr/abl, r = 0.96, indicating a precise log-linear relation for 10-10(5) copies/100 ng of cDNA. In the same PCR reactions, r = 0.99 for beta-actin (coamplified with M-bcr/abl or m-bcr/abl) for 10(3)-10(7) copies/100 ng cDNA. The linear correlation coefficient for single and duplex measurements was 0.98 for M- and m-bcr/abl in patient samples.
CONCLUSIONS: DABCYL can be used as dark quencher fluorophore in real-time fluorescence PCR. The duplex fluorescence RT-PCR assay for bcr/abl and beta-actin transcripts allows monitoring of bcr/abl+ leukemias.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11238301

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  Quantification of bcl-2/JH fusion sequences and a control gene by multiplex real-time PCR coupled with automated amplicon sizing by capillary electrophoresis.

Authors:  Beatriz Sanchez-Vega; Francisco Vega; L Jeffrey Medeiros; Ming S Lee; Rajyalakshmi Luthra
Journal:  J Mol Diagn       Date:  2002-11       Impact factor: 5.568

2.  Quantitation of cytomegalovirus (hCMV) DNA and beta-actin DNA by duplex real-time fluorescence PCR in solid organ (liver) transplant recipients.

Authors:  Joachim Hänfler; Karl Anton Kreuzer; Katja Laurisch; Nada Rayes; Peter Neuhaus; Christian Andreas Schmidt; Helmut Oettle
Journal:  Med Microbiol Immunol       Date:  2003-01-30       Impact factor: 3.402

3.  Advantages of Amplifluor-like SNP markers over KASP in plant genotyping.

Authors:  Satyvaldy Jatayev; Akhylbek Kurishbayev; Lyudmila Zotova; Gulmira Khasanova; Dauren Serikbay; Askar Zhubatkanov; Makpal Botayeva; Aibek Zhumalin; Arysgul Turbekova; Kathleen Soole; Peter Langridge; Yuri Shavrukov
Journal:  BMC Plant Biol       Date:  2017-12-28       Impact factor: 4.215

4.  Modified "Allele-Specific qPCR" Method for SNP Genotyping Based on FRET.

Authors:  Ruslan Kalendar; Akmaral Baidyussen; Dauren Serikbay; Lyudmila Zotova; Gulmira Khassanova; Marzhan Kuzbakova; Satyvaldy Jatayev; Yin-Gang Hu; Carly Schramm; Peter A Anderson; Colin L D Jenkins; Kathleen L Soole; Yuri Shavrukov
Journal:  Front Plant Sci       Date:  2022-01-10       Impact factor: 5.753

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.