Literature DB >> 11237913

Stereo nonmydriatic digital-video color retinal imaging compared with Early Treatment Diabetic Retinopathy Study seven standard field 35-mm stereo color photos for determining level of diabetic retinopathy.

S E Bursell1, J D Cavallerano, A A Cavallerano, A C Clermont, D Birkmire-Peters, L P Aiello, L M Aiello.   

Abstract

OBJECTIVE: To evaluate the ability to determine clinical levels of diabetic retinopathy, timing of next appropriate retinal evaluation, and necessity of referral to ophthalmology specialists using stereoscopic nonmydriatic digital-video color retinal images as compared with Early Treatment Diabetic Retinopathy Study (ETDRS) seven standard field 35-mm stereoscopic color fundus photographs.
DESIGN: Prospective, clinic-based, comparative instrument validation study. PARTICIPANTS: Fifty-four patients (108 eyes) with type 1 or type 2 diabetes mellitus selected after chart review from a single center to include the full spectrum of diabetic retinopathy.
METHODS: Nonsimultaneous 45 degrees -field stereoscopic digital-video color images (JVN images) were obtained from three fields with the Joslin Vision Network (JVN) system before pupil dilation. Following pupil dilation, ETDRS seven standard field 35-mm stereoscopic color 30 degrees fundus photographs (ETDRS photos) were obtained. Joslin Vision Network images and ETDRS photos were graded on a lesion-by-lesion basis by two independent, masked readers to assess ETDRS clinical level of diabetic retinopathy. An independent ophthalmology retina specialist adjudicated interreader disagreements in a masked fashion. MAIN OUTCOME MEASURES: Determination of ETDRS clinical level of diabetic retinopathy, timing of next ophthalmic evaluation of diabetic retinopathy, and need for prompt referral to ophthalmology specialist.
RESULTS: There was substantial agreement (kappa = 0.65) between the clinical level of diabetic retinopathy assessed from the undilated JVN images and the dilated ETDRS photos. Agreement was excellent (kappa = 0.87) for suggested referral to ophthalmology specialists for eye examinations. Comparison of individual lesions between the JVN images and the ETDRS photos and for interreader comparisons were comparable to the prior ETDRS study.
CONCLUSIONS: Undilated digital-video images using the JVN system were comparable photographs for the determination of diabetic retinopathy level. The results validate the agreement between nonmydriatic JVN images and dilated ETDRS photographs and suggest that this digital technique may be an effective telemedicine tool for remotely determining the level of diabetic retinopathy, suggesting timing of next retinal evaluation and identifying the need for prompt referral to ophthalmology specialists. Thus, the JVN system would be an appropriate tool for facilitating increased access of diabetic patients into recommended eye evaluations, but should not be construed as a paradigm that would replace the need for comprehensive eye examinations.

Entities:  

Mesh:

Year:  2001        PMID: 11237913     DOI: 10.1016/s0161-6420(00)00604-7

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  47 in total

1.  Comparison of autophotomontage software programs in eyes with CMV retinitis.

Authors:  Jenny Chen; Somsanguan Ausayakhun; Sakarin Ausayakhun; Choeng Jirawison; Claire M Khouri; Travis C Porco; David Heiden; Jeremy D Keenan; Todd P Margolis
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-12-09       Impact factor: 4.799

Review 2.  Role of health information technologies in the Patient-centered Medical Home.

Authors:  Jennifer L Kraschnewski; Robert A Gabbay
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

3.  Innovation in Indian healthcare: using health information technology to achieve health equity for American Indian and Alaska Native populations.

Authors:  Mark Carroll; Theresa Cullen; Stewart Ferguson; Nathan Hogge; Mark Horton; John Kokesh
Journal:  Perspect Health Inf Manag       Date:  2011-01-01

4.  Utility of hard exudates for the screening of macular edema.

Authors:  Taras V Litvin; Glen Y Ozawa; George H Bresnick; Jorge A Cuadros; Matthew S Muller; Ann E Elsner; Thomas J Gast
Journal:  Optom Vis Sci       Date:  2014-04       Impact factor: 1.973

5.  Comparison of image-assisted versus traditional fundus examination.

Authors:  Kristen Brown; Jeanette M Sewell; Clement Trempe; Tunde Peto; Thomas G Travison
Journal:  Eye Brain       Date:  2013-02-13

6.  A renaissance of teleophthalmology through artificial intelligence.

Authors:  Edward Korot; Edward Wood; Adam Weiner; Dawn A Sim; Michael Trese
Journal:  Eye (Lond)       Date:  2019-01-08       Impact factor: 3.775

7.  The accuracy of digital-video retinal imaging to screen for diabetic retinopathy: an analysis of two digital-video retinal imaging systems using standard stereoscopic seven-field photography and dilated clinical examination as reference standards.

Authors:  Mary Gilbert Lawrence
Journal:  Trans Am Ophthalmol Soc       Date:  2004

8.  Assessing diabetic retinopathy using two-field digital photography and the influence of JPEG-compression.

Authors:  Catharina Stellingwerf; Peter L L J Hardus; Johanna M M Hooymans
Journal:  Doc Ophthalmol       Date:  2004-05       Impact factor: 2.379

9.  Influence of diabetes and diabetes type on anatomic and visual outcomes following central rein vein occlusion.

Authors:  J G Santiago; S Walia; J K Sun; J D Cavallerano; Z A Haddad; L P Aiello; P S Silva
Journal:  Eye (Lond)       Date:  2014-02-14       Impact factor: 3.775

10.  Accuracy of digital images for assessing diabetic retinopathy.

Authors:  Hyungjin Myra Kim; Julie C Lowery; Ronald Kurtz
Journal:  J Diabetes Sci Technol       Date:  2007-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.