Literature DB >> 11236893

Generalized optimal current patterns and electrical safety in EIT.

W R Lionheart1, J Kaipio, C N McLeod.   

Abstract

There are a number of constraints which limit the current and voltages which can be applied on a multiple drive electrical imaging system. One obvious constraint is to limit the maximum ohmic power dissipated in the body. Current patterns optimizing distinguishability with respect to this constraint are singular functions of the difference of transconductance matrices with respect to the power norm (the optimal currents of Isaacson). If one constrains the total current (L1 norm) the optimal patterns are pair drives. On the other hand if one constrains the maximum current on each drive electrode (an L(infinity) norm), the optimal patterns have each drive channel set to the maximum source or sink current value. In this paper we consider appropriate safety constraints and discuss how to find the optimal current patterns with those constraints.

Mesh:

Year:  2001        PMID: 11236893     DOI: 10.1088/0967-3334/22/1/311

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  8 in total

1.  Design of electrodes and current limits for low frequency electrical impedance tomography of the brain.

Authors:  O Gilad; L Horesh; D S Holder
Journal:  Med Biol Eng Comput       Date:  2007-06-28       Impact factor: 2.602

2.  MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

Authors:  V E Arpinar; M J Hamamura; E Degirmenci; L T Muftuler
Journal:  Phys Med Biol       Date:  2012-06-08       Impact factor: 3.609

3.  Incorporating a biopsy needle as an electrode in transrectal electrical impedance imaging.

Authors:  Yuqing Wan; Andrea Borsic; Alex Hartov; Ryan Halter
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

4.  Electrical Impedance Tomography-Based Abdominal Subcutaneous Fat Estimation Method Using Deep Learning.

Authors:  Kyounghun Lee; Minha Yoo; Ariungerel Jargal; Hyeuknam Kwon
Journal:  Comput Math Methods Med       Date:  2020-06-11       Impact factor: 2.238

5.  A Low-Power Stable Wideband Current Source for Acupuncture Point Skin Impedance Measurements.

Authors:  Changpei Qiu; Tianxia Zhao; Qiuping Li; Xin'an Wang; Kanglin Xiao; Bo Wang
Journal:  J Healthc Eng       Date:  2021-01-06       Impact factor: 2.682

6.  Applications of Bioimpedance Measurement Techniques in Tissue Engineering.

Authors:  M Amini; J Hisdal; H Kalvøy
Journal:  J Electr Bioimpedance       Date:  2018-12-31

7.  Frequency-division multiplexing for electrical impedance tomography in biomedical applications.

Authors:  Yair Granot; Antoni Ivorra; Boris Rubinsky
Journal:  Int J Biomed Imaging       Date:  2007

8.  Simple Wireless Impedance Pneumography System for Unobtrusive Sensing of Respiration.

Authors:  Pablo Aqueveque; Britam Gómez; Emyrna Monsalve; Enrique Germany; Paulina Ortega-Bastidas; Sebastián Dubo; Esteban J Pino
Journal:  Sensors (Basel)       Date:  2020-09-14       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.