Literature DB >> 11236881

Influence of overlying tissue and probe geometry on the sensitivity of a near-infrared tissue oximeter.

W Feng1, D Haishu, T Fenghua, Z Jun, X Qing, T Xianwu.   

Abstract

In this paper, the influences of overlying tissue and detecting distance between the source and the detector on the measurement of a tissue oximeter were discussed. The signal-noise-ratio of the detector was also examined. A semi-infinite multi-layer Monte Carlo model was induced to simulate the migration of the photons in the skin, adipose and muscle. The thickness of the adipose layer and the separation between the source and the detector in the muscle were changed to simulate the clinical application. Partial pathlength was introduced as a characteristic parameter to evaluate the sensitivity of the oximeter. A two-wavelength (700 and 830 nm) tissue oximeter was developed to verify the results of the simulation. The Monte Carlo simulation results showed that the sensitivity of the near infrared spectroscopy (NIRS) oximeter declined greatly with increasing overlying tissue thickness. Increasing the distance between the light source and the detector improved the sensitivity. However, in order to achieve a sufficiently high signal-to-noise ratio, it was necessary to limit this distance. The results of a bicycle ergometer exercise verified the above results and showed that, for a special adipose thickness (AT), there may be a reasonable range of the emitter-detector separation.

Mesh:

Substances:

Year:  2001        PMID: 11236881     DOI: 10.1088/0967-3334/22/1/323

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Effect of moderate altitude on peripheral muscle oxygenation during leg resistance exercise in young males.

Authors:  Kazuo Oguri; Na Du; Yoshihiro Kato; Kei Miyamoto; Takahiro Masuda; Katsuji Shimizu; Toshio Matsuoka
Journal:  J Sports Sci Med       Date:  2004-09-01       Impact factor: 2.988

2.  Non-invasive quantitative assessment of oxidative metabolism in quadriceps muscles by near infrared spectroscopy.

Authors:  H Ding; G Wang; W Lei; R Wang; L Huang; Q Xia; J Wu
Journal:  Br J Sports Med       Date:  2001-12       Impact factor: 13.800

3.  Pronounced muscle deoxygenation during supramaximal exercise under simulated hypoxia in sprint athletes.

Authors:  Kazuo Oguri; Hajime Fujimoto; Hiroyuki Sugimori; Kei Miyamoto; Toshiki Tachi; Sachio Nagasaki; Yoshihiro Kato; Toshio Matsuoka
Journal:  J Sports Sci Med       Date:  2008-12-01       Impact factor: 2.988

4.  Real-time Vessel Navigation Using Indocyanine Green Fluorescence during Robotic or Laparoscopic Gastrectomy for Gastric Cancer.

Authors:  Mina Kim; Sang-Yong Son; Long-Hai Cui; Ho-Jung Shin; Hoon Hur; Sang-Uk Han
Journal:  J Gastric Cancer       Date:  2017-06-09       Impact factor: 3.720

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.