Literature DB >> 11234942

Migration of a K-wire from the distal radius to the heart.

R C Seipel1, G J Schmeling, R A Daley.   

Abstract

K-wires and Steinmann pins are used to provide internal fixation for fractures or osteotomies. In some instances, removal of the implant is planned and the implant is left long to facilitate its removal. In other instances, implant removal is not planned and the implant is cut off at the level of the bone. Migration of these implants to solid organs or body cavities has been reported. Extravascular migration may occur along tissue planes assisted by muscle motion. Large vessel penetration can occur and has been reported with subsequent migration of the implant to the heart. This case report documents the loosening of a K-wire used in the distal radius to supplement the fixation of a complex intra-articular fracture, migration of the implant along tissue planes, penetration into a peripheral vein, and continued migration of the implant to the heart. There are multiple reports documenting wandering bullets, venous catheter tips, and invasive monitoring devices in the extremities. This is only the second case report that the authors are aware of that confirms migration of an implant from the distal extremity to the heart.

Entities:  

Mesh:

Year:  2001        PMID: 11234942

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  6 in total

1.  Haemopericardium causing cardiac tamponade: a late complication of pectus excavatum repair.

Authors:  M J Barakat; J A Morgan
Journal:  Heart       Date:  2004-04       Impact factor: 5.994

2.  A review of K-wire related complications in the emergency management of paediatric upper extremity trauma.

Authors:  H Sharma; G R Taylor; N M P Clarke
Journal:  Ann R Coll Surg Engl       Date:  2007-04       Impact factor: 1.891

3.  Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report.

Authors:  Ekrem Aydın; Turan Cihan Dülgeroğlu; Hasan Metineren
Journal:  J Med Case Rep       Date:  2016-02-24

4.  Broken Pieces of Circlage Wire Lying in Soft Tissue Envelope Around Knee Joint: A Case Report and Review of Literature.

Authors:  Anoop Kalia; Kavin Khatri; Jagdeep Singh; Kapil Bansal; Mohammed Sagy
Journal:  J Orthop Case Rep       Date:  2016 Jul-Aug

5.  Death Due to Intra-aortic Migration of Kirschner Wire From the Clavicle: A Case Report and Review of the Literature.

Authors:  Lei Tan; Da-Hui Sun; Tiecheng Yu; Linxiang Wang; Dong Zhu; Yan-Hui Li
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

6.  Broken Kirschner Wires Can Migrate: A Case Report and Review of Literature.

Authors:  Mir Sadat-Ali; Abdullah M Shehri; Mohammed A AlHassan; Khalid AlTabash; Fatema Abdul Mohsen Mohamed; Mohamed Mokhles Aboutaleb; Ali A AlGhanim
Journal:  J Orthop Case Rep       Date:  2020-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.