Literature DB >> 11234920

Clinical and analytical evaluation of the simultaneous HPLC assay of retinol and alpha-tocopherol.

H Ihara1, H Ishigaki, N Shino YHashizume, M Takase, J Nagao, Y Sumiyama.   

Abstract

We describe a method for the simultaneous assay of retinol and alpha-tocopherol using normal-phase, high-performance liquid chromatography (HPLC). Our normal-phase HPLC method gave better resolution (Rs) of retinol (Rs= 1.58) and alpha-tocopherol (Rs = 1.40) when compared with the Rs values for a-tocopherol and retinol from literature. Also, the alpha-tocopherol concentrations obtained by our method agreed well with another normal-phase HPLC method that used fluorometric detection (r = 0.951, p<0.001. Sy.x=0.58 mg/L). The concentrations of retinol in our method agreed well with those determined by a reversed-phase HPLC procedure, although the correlation (r=0.646, p<.001, Sy.x=62 microg/L) was not as good as the method proposed. Our procedure gave acceptable precision: the within-run CV was 7.7% for alpha-tocopherol and 5.9% for retinol. The between-day CV was 9.0% for alpha-tocopherol and 6.8% for retinol. The mean recoveries were 97% for alpha-tocopherol and 107% for retinol. Our assays were linear for alpha-tocopherol concentrations from 0.1 to 30 mg/L and for retinol concentrations from 20 to 2,000 microg/L. In children ages 7 to 12 y, and in adolescents ages 14 to 16 y, the alpha-tocopherol and retinol concentrations in the blood were significantly lower than the concentrations in normal adults. Individuals over 70 y old also showed alpha-tocopherol and retinol values that were lower than those of normal adults between ages 30 and 40 y. In female university students, the inter-individual variation of alpha-tocopherol was reduced by dividing the alpha-tocopherol results by their total cholesterol or total lipid concentrations; however, this was not obtained for retinol. In cancer patients undergoing surgery, the ratio of retinol to retinol-binding protein (RBP) remained fairly constant, although the concentrations of both retinol and RBP decreased to about one-half the preoperative values after surgery. We conclude that our normal-phase HPLC method is a stable and reproducible method for alpha-tocopherol and retinol, and is an easy-to-use analytical tool.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11234920     DOI: 10.3177/jnsv.46.257

Source DB:  PubMed          Journal:  J Nutr Sci Vitaminol (Tokyo)        ISSN: 0301-4800            Impact factor:   2.000


  3 in total

1.  Simultaneous analysis of circulating 25-hydroxy-vitamin D3, 25-hydroxy-vitamin D2, retinol, tocopherols, carotenoids, and oxidized and reduced coenzyme Q10 by high performance liquid chromatography with photo diode-array detection using C18 and C30 columns alone or in combination.

Authors:  Adrian A Franke; Cynthia M Morrison; Laurie J Custer; Xingnan Li; Jennifer F Lai
Journal:  J Chromatogr A       Date:  2013-06-12       Impact factor: 4.759

2.  A validated liquid chromatography method for the simultaneous determination of vitamins A and E in human plasma.

Authors:  Danuta Siluk; Regina V Oliveira; Maria Esther-Rodriguez-Rosas; Shari Ling; Angelo Bos; Luigi Ferrucci; Irving W Wainer
Journal:  J Pharm Biomed Anal       Date:  2007-04-04       Impact factor: 3.935

3.  Stability of fat-soluble and water-soluble vitamins in artificially prepared, vitamin-enriched, lyophilized serum.

Authors:  Hiroshi Ihara; Naotaka Hashizume; Tadashi Matsubayashi; Koichi Futaki; Masayuki Yoshida; Naotoshi Sagawa; Makoto Fujisaki; Kazuo Mita; Akira Kadota
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.