Literature DB >> 11233478

[Measurement of left atrial and ventricular volumes in real-time 3D echocardiography. Validation by nuclear magnetic resonance].

F Bauer1, T Shiota, J X Qin, R D White, J D Thomas.   

Abstract

The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.

Entities:  

Keywords:  NASA Discipline Cardiopulmonary; Non-NASA Center

Mesh:

Year:  2001        PMID: 11233478

Source DB:  PubMed          Journal:  Arch Mal Coeur Vaiss        ISSN: 0003-9683


  3 in total

1.  Volume measurements in nuclear medicine gated SPECT and 4D echocardiography: validation using a dynamic cardiac phantom.

Authors:  Dominique Debrun; Fabienne Thérain; Long-Dang Nguyen; Christophe P Léger; Jacco J N Visser; Ellinor Busemann-Sokole
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

2.  Early assessment of percutaneous coronary interventions for chronic total occlusions analyzed by novel echocardiographic techniques.

Authors:  Ercan Erdogan; Mehmet Akkaya; Ahmet Bacaksiz; Abdurrrahman Tasal; Osman Sönmez; Mehmet Ali Elbey; Seref Kul; Mehmet Akif Vatankulu; Murat Turfan; Ömer Göktekin
Journal:  Clinics (Sao Paulo)       Date:  2013-10       Impact factor: 2.365

3.  Respiratory influence on left atrial volume calculation with 3D-echocardiography.

Authors:  Mathias Sørgaard; Jesper J Linde; Hafsa Ismail; Niels Risum; Klaus F Kofoed; Jørgen T Kühl; Benjamin Tittle; Walter B Nielsen; Jens D Hove
Journal:  Cardiovasc Ultrasound       Date:  2016-03-12       Impact factor: 2.062

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.