Literature DB >> 11229955

Routine carbon monoxide screening by emergency medical technicians.

D Jaslow1, J Ufberg, J Ukasik, P Sananman.   

Abstract

UNLABELLED: Residential carbon monoxide (CO) poisoning represents a significant cause of unintentional morbidity and mortality in the United States. Screening by fire departments and utility companies is usually limited to instances in which there are symptoms of CO poisoning or there is activation of a home CO detector.
OBJECTIVES: To determine whether emergency medical services (EMS) personnel can perform routine CO screening during 911 calls.
METHODS: A prospective observational study was conducted in an urban EMS system using emergency medical technicians (EMTs) to screen for elevated CO levels during emergency responses. The EMTs carried hand-held CO meters that detect as little as one part per million of CO. Readings were taken at the patient's side during indoor patient contacts. If time allowed, a brief questionnaire was then administered to patients or by-standers concerning knowledge about CO poisoning, type of household heating system, and presence of home CO detectors.
RESULTS: In a three-month convenience sample of emergency responses, there were 264 residential CO readings obtained. There were nine (3.4%) positive residential readings, all with chief complaints believed to be unrelated to CO toxicity. Two hundred twelve surveys were completed during these emergency responses, with 145 of 212 (68%) participants familiar with the term "carbon monoxide poisoning." Only 54 of 145 (37%) participants could name any signs or symptoms of CO poisoning. Of those surveyed, 133 of 212 (63%) participants reported an oil- or gas-powered heating system in their residence. Carbon monoxide detectors were absent in 185 of 212 (87%) residences, including all domiciles in which a positive CO reading was obtained.
CONCLUSIONS: Emergency medical services personnel can perform routine CO screening and detect occult elevations in CO levels during 911 responses. Public knowledge of CO poisoning is limited and the use of home CO detectors is rare in this study population.

Entities:  

Mesh:

Year:  2001        PMID: 11229955     DOI: 10.1111/j.1553-2712.2001.tb01309.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  3 in total

1.  The formation of the emergency medical services system.

Authors:  Manish N Shah
Journal:  Am J Public Health       Date:  2006-01-31       Impact factor: 9.308

2.  Do emergency medical services professionals think they should participate in disease prevention?

Authors:  E Brooke Lerner; Antonio R Fernandez; Manish N Shah
Journal:  Prehosp Emerg Care       Date:  2009 Jan-Mar       Impact factor: 3.077

Review 3.  Which extended paramedic skills are making an impact in emergency care and can be related to the UK paramedic system? A systematic review of the literature.

Authors:  Rachel Evans; Ruth McGovern; Jennifer Birch; Dorothy Newbury-Birch
Journal:  Emerg Med J       Date:  2013-04-10       Impact factor: 2.740

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.