Literature DB >> 11227598

Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder. Reveal-Investigators.

K Seidl1, M Rameken, S Breunung, J Senges, W Jung, D Andresen, A van Toor, A D Krahn, G J Klein.   

Abstract

AIM: Patients with recurrent syncope undiagnosed after extensive non-invasive and invasive testing pose a diagnostic and therapeutic dilemma. Holter monitoring is nondiagnostic in 90% of cases. Recent developments in loop recorder technology permit long-term ECG monitoring in patients with recurrent unexplained syncope. The aim of this study was to report the worldwide experience with a new subcutaneously implantable loop recorder, implanted in 133 patients with unexplained syncope and negative laboratory investigations. METHODS AND
RESULTS: The implantable loop recorder monitors continuously a single lead electrogram using two sensing electrodes on the device shell. The device was implanted in 133 patients, 67 male and 66 female with recurrent syncope. During a mean follow-up of 10.8 +/- 4.3 months after device implantation, 83 patients (62%) experienced syncope or pre-syncope. In the remaining 50 patients no diagnosis could be made because either no events occurred, the patients were lost to follow-up, had adverse events, or died prior to diagnosis. In 72 of the 83 patients with syncope during follow-up (87%), loop recording definitively determined whether an arrhythmia was the cause of symptoms or not. Diagnosis included bradycardia in 21 patients, pacemaker dysfunction in one patient, and tachycardia in 10 patients. One patient experienced multiple rhythm disturbances. Syncope was non-arrhythmic in 40 patients. The remaining 11 patients failed to press the activator. Therapy was instituted in all patients, in whom an arrhythmic cause was found. Severe anticipated device related complications occurred in three patients.
CONCLUSION: An implantable loop recorder is useful for establishing a diagnosis when symptoms are recurrent but too infrequent for conventional monitoring techniques.

Entities:  

Mesh:

Year:  2000        PMID: 11227598     DOI: 10.1053/eupc.2000.0108

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  8 in total

1.  [Commentary on the guidelines the diagnosis and the therapy of syncope--the European Society of Cardiology 2001 and the update 2004].

Authors:  K Seidl; A Schuchert; J Tebbenjohanns; W Hartung
Journal:  Z Kardiol       Date:  2005-09

2.  Patient selection for ambulatory cardiac monitoring in the Indian healthcare environment.

Authors:  Maneesh Shrivastav; Rajendra Shrivastav; Jitendra Makkar; Mauro Biffi
Journal:  Heart Asia       Date:  2013-01-27

Review 3.  [Event-recorder].

Authors:  Andreas Schuchert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-10-25

4.  Implantable loop recorders: a novel method to judge patient perception of atrial fibrillation. Preliminary results from a pilot study.

Authors:  Annibale S Montenero; Abdul Quayyum; Pasquale Franciosa; Daniele Mangiameli; Andrea Antonelli; Luca Barbieri; Nicola Bruno; Francesco Zumbo; Marco Vimercati
Journal:  J Interv Card Electrophysiol       Date:  2004-06       Impact factor: 1.900

Review 5.  Implantable diagnostic monitoring devices for evaluation of syncope, and tachy- and brady-arrhythmias.

Authors:  David G Benditt; Cengiz Ermis; Scott Pham; Laura Hiltner; Amy Vrudney; Keith G Lurie; Scott Sakaguchi
Journal:  J Interv Card Electrophysiol       Date:  2003-10       Impact factor: 1.900

6.  Holding Area LINQ Trial (HALT).

Authors:  John J Lee; Daniel Weitz; Rishi Anand
Journal:  Indian Pacing Electrophysiol J       Date:  2017-06-23

Review 7.  Insertion of miniaturized cardiac monitors outside the catheter operating room: experience and practical advice.

Authors:  Jan Steffel; David Jay Wright; Harald Schäfer; Tabinda Rashid-Fadel; Thorsten Lewalter
Journal:  Europace       Date:  2017-10-01       Impact factor: 5.214

8.  Implant evaluation of an insertable cardiac monitor outside the electrophysiology lab setting.

Authors:  Roman Pachulski; James Cockrell; Hemant Solomon; Fang Yang; John Rogers
Journal:  PLoS One       Date:  2013-08-15       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.