Literature DB >> 11226797

One year results of European Multicenter Study of intrastromal corneal ring segments. Part 2: complications, visual symptoms, and patient satisfaction.

J Ruckhofer1, J Stoiber, E Alzner, G Grabner.   

Abstract

PURPOSE: To assess intraoperative and postoperative complications, visual symptoms, and patient satisfaction after implantation of intrastromal corneal ring segments (ICRS, KeraVision, Inc.) for the correction of myopia and to demonstrate the reversibility and adjustability of refractive corrections with this method.
SETTING: Twelve European investigational sites.
METHODS: Patients with myopia of -1.0 to -6.0 diopters (D) were assigned to receive 1 of 5 ICRS thicknesses (0.25, 0.30, 0.35, 0.40, or 0.45 mm). Complications and visual symptoms were noted, and patient satisfaction was assessed at each postoperative visit (1 and 7 days and 1, 2, 3, 6, and 12 months). Refractive data were assessed after removal or exchange of the ICRS.
RESULTS: Of 163 eyes of 110 patients enrolled, 159 eyes of 107 patients were implanted with an ICRS (52 patients had bilateral implantation). Intraoperative complications occurred in 2% of eyes (4/163 eyes in 3 patients) that were withdrawn from the study: 3 eyes had anterior surface perforations and 1 had a posterior microperforation into the anterior chamber. Most patients had no visual symptoms at 12 months; symptoms usually occurred rarely or sometimes and were mild in severity. At 12 months, good or excellent patient satisfaction was reported for 94% of eyes. Twelve ICRSs (8%) were removed, mainly because of undercorrection and induced astigmatism, and 2 were exchanged. All eyes were within +/-1.00 D of the preoperative manifest refraction spherical equivalent.
CONCLUSIONS: The ICRS was safe for correction of low to moderate myopia. Severe postoperative visual symptoms were rare, and patient satisfaction was high. The refractive correction was largely reversible.

Entities:  

Mesh:

Year:  2001        PMID: 11226797     DOI: 10.1016/s0886-3350(00)00740-9

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  15 in total

1.  Visual outcomes after femtosecond-assisted intracorneal MyoRing implantation: 18 months of follow-up.

Authors:  Masoomeh Mohebbi; Hassan Hashemi; Soheila Asgari; Sara Bigdeli; Kambiz Ameli Zamani
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-29       Impact factor: 3.117

2.  Optical coherence tomography to assess intrastromal corneal ring segment depth in keratoconic eyes.

Authors:  Michael M Lai; Maolong Tang; Eduardo M M Andrade; Yan Li; Rahul N Khurana; Jonathan C Song; David Huang
Journal:  J Cataract Refract Surg       Date:  2006-11       Impact factor: 3.351

3.  Intrastromal corneal ring implants for corneal thinning disorders: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-04-01

4.  Intrastromal corneal ring segment implantation (keraring 355°) in patients with central keratoconus: 6-month follow-up.

Authors:  Khosrow Jadidi; Seyed Aliasghar Mosavi; Farhad Nejat; Mostafa Naderi; Leila Janani; Sara Serahati
Journal:  J Ophthalmol       Date:  2015-01-05       Impact factor: 1.909

5.  Novel technique of fixing intracorneal rings segments after migration.

Authors:  Prateek Agarwal; Praveen Subudhi; Neha Mithal
Journal:  BMJ Case Rep       Date:  2020-01-15

6.  Post intrastromal corneal ring segments insertion complicated by Candida parapsilosis keratitis.

Authors:  Bradley M Mitchell; A John Kanellopoulos; Ramon L Font
Journal:  Clin Ophthalmol       Date:  2013-02-28

7.  A new measure of patient satisfaction with ocular hypotensive medications: the Treatment Satisfaction Survey for Intraocular Pressure (TSS-IOP).

Authors:  Mark J Atkinson; William C Stewart; Joel M Fain; Jeanette A Stewart; Ravinder Dhawan; Essy Mozaffari; Jan Lohs
Journal:  Health Qual Life Outcomes       Date:  2003-11-15       Impact factor: 3.186

8.  Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique.

Authors:  Zeki Tunc; Firat Helvacioglu; Sadik Sencan
Journal:  Indian J Ophthalmol       Date:  2013-05       Impact factor: 1.848

Review 9.  Advances in femtosecond laser technology.

Authors:  Thais Pinheiro Callou; Renato Garcia; Adriana Mukai; Natalia T Giacomin; Rodrigo Guimarães de Souza; Samir J Bechara
Journal:  Clin Ophthalmol       Date:  2016-04-19

10.  Clinical outcomes after intracorneal ring segment implantation for keratoconus management in corneas with mild apical haze.

Authors:  Mohamed Elalfy; Sundas Maqsood; Aja Reinhold; Georgios D Panos; Aye Khine; Damian Lake; Samer Hamada; Zisis Gatzioufas
Journal:  Ther Adv Ophthalmol       Date:  2021-03-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.