Age- and body mass index-related changes in cutaneous shear wave velocity.

T Hermanns-Lê1, F Jonlet, A Scheen, G E Piérard.   

Abstract

BACKGROUND: The in vivo visco-elastic characteristics of skin depend on a series of physiopathological parameters. Among them, the age-related intrinsic tensile properties and the preconditioning of the tissues set under tension by the hypodermal volume might be of importance. AIMS: To revisit the influence of age and body mass on the firmness and mechanical anisotropy of the skin as determined by the velocity of the shear wave propagation.
METHOD: Resonance running time measurements (RRTM) were performed on the mid volar forearm in 110 adults of both sexes. In each subject 16 RRTM were collected at four different precise angles with regard to the limb axis. We recorded the lowest, the highest and the mean multidirectional RRTM as well as the coefficient of variation (CV) of the latter value. In addition, the body mass index (BMI) was calculated.
RESULTS: Age and BMI did not influence the minimum RRTM. In contrast, the maximum RRTM as well as the mean and CV of the multidirectional RRTM, significantly rose in a progressively increasing proportion of the subjects older than 60 years. These changes were only encountered in subjects with a normal BMI ranging from 18 to 25. Sex-related differences were not disclosed.
CONCLUSIONS: The intrinsic skin tension lines identified by the minimum RRTM are not significantly altered with age and BMI variations. In contrast, skin laxity identified by larger maximum and mean multidirectional RRTM may increase after 60 years of age in subjects with a normal BMI. This is accompanied by increased skin mechanical anisotropy identified by CV values of the multidirectional RRTM over 40%.

Entities:  

Mesh:

Year:  2001        PMID: 11226749     DOI: 10.1016/s0531-5565(00)00219-9

Source DB:  PubMed          Journal:  Exp Gerontol        ISSN: 0531-5565            Impact factor:   4.032


  3 in total

1.  Cutaneous resonance running time varies with age, body site and gender in a normal Chinese population.

Authors:  Shujun Xin; Wenyan Man; Joachim W Fluhr; Shunpeng Song; Peter M Elias; Mao-Qiang Man
Journal:  Skin Res Technol       Date:  2010-11       Impact factor: 2.365

2.  Posture-related Displacement of Subclavian Catheter in Obese Patients.

Authors:  Mohammad Salman Mirza; Mohammad Shafiq
Journal:  Sultan Qaboos Univ Med J       Date:  2009-03-16

3.  The effect of dietary and/or cosmetic argan oil on postmenopausal skin elasticity.

Authors:  Kenza Qiraouani Boucetta; Zoubida Charrouf; Hassan Aguenaou; Abdelfattah Derouiche; Yahya Bensouda
Journal:  Clin Interv Aging       Date:  2015-01-30       Impact factor: 4.458

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.