New neuroretinal rim blood flow evaluation method combining Heidelberg retina flowmetry and tomography.

C P Jonescu-Cuypers1, H S Chung, L Kagemann, Y Ishii, D Zarfati, A Harris.   

Abstract

AIM: Accurate Heidelberg retina flowmeter (HRF) measurements require correct manual setting of the HRF photodetector sensitivity. The neuroretinal rim produces a weak signal relative to the peripapillary retina. A newly developed HRF alignment and sensitivity protocol, capable of accurate rim measurement, was investigated.
METHODS: 18 eyes of nine healthy volunteers were examined by HRF. Three images of each eye were taken using three different imaging methods. Method 1: a conventional image (optic nerve head centred image with photodetector sensitivity optimised for the strong signal from the peripapillary retina); method 2: the setting of method 1 with photodetector sensitivity optimised for the weak signal from the rim; and method 3: the setting of method 2 with the temporal rim margin tangent to the lateral image border to remove the overpowering signal from the temporal peripapillary retina. The neuroretinal rim was defined by the Heidelberg retina tomograph (HRT). Blood flow and reflectivity values (DC component) in the rim area were compared for the three methods using pointwise analysis. Coefficients of variation of repeated measurements in 12 subjects have been calculated for method 3.
RESULTS: The neuroretinal rim area measured by method 1 had a significantly lower brightness compared with method 2 and 3 (p=0.0002 and p=0.0002, respectively). Method 2 provided proper sensitivity for the weak signals of the rim area based on rim tissue DC values; however, this sensitivity setting was too high for the strong signal from the peripapillary retina. Method 3 avoided the strong peripapillary signal with the proper signal from the rim and provided significantly higher flow values of the rim area at 75 and 90 percentile pixels (p=0.0065 and p=0.0038 respectively) compared with method 2. Interobserver repeatability ranged from 16.85% to 21.96% for the different parameters.
CONCLUSIONS: Method 3 provides an accurate and reproducible flow measurement of the neuroretinal rim area through proper sensitivity for the weak rim signal, alignment, and removal of the strong temporal signal from the image. This new method is recommended to improve accuracy of blood flow measurement in the neuroretinal rim.

Entities:  

Mesh:

Year:  2001        PMID: 11222335      PMCID: PMC1723875          DOI: 10.1136/bjo.85.3.304

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  23 in total

1.  [Effect of the contour line on cup surface using the Heidelberg Retina Tomograph].

Authors:  K U Bartz-Schmidt; C P Jonescu-Cuypers; G Thumann; J Frucht; G K Krieglstein
Journal:  Klin Monbl Augenheilkd       Date:  1996-11       Impact factor: 0.700

2.  Principle, validity, and reliability of scanning laser Doppler flowmetry.

Authors:  G Michelson; B Schmauss; M J Langhans; J Harazny; M J Groh
Journal:  J Glaucoma       Date:  1996-04       Impact factor: 2.503

3.  Clinical investigation of the combination of a scanning laser ophthalmoscope and laser Doppler flowmeter.

Authors:  G Michelson; M J Langhans; M J Groh
Journal:  Ger J Ophthalmol       Date:  1995-11

4.  Reproducibility of retinal and optic nerve head blood flow measurements with scanning laser Doppler flowmetry.

Authors:  M T Nicolela; P Hnik; M Schulzer; S M Drance
Journal:  J Glaucoma       Date:  1997-06       Impact factor: 2.503

5.  Reproducibility and sensitivity of scanning laser Doppler flowmetry during graded changes in PO2.

Authors:  K Strenn; R Menapace; G Rainer; O Findl; M Wolzt; L Schmetterer
Journal:  Br J Ophthalmol       Date:  1997-05       Impact factor: 4.638

6.  The effect of optic disc size on diagnostic precision with the Heidelberg retina tomograph.

Authors:  M Iester; F S Mikelberg; S M Drance
Journal:  Ophthalmology       Date:  1997-03       Impact factor: 12.079

7.  Confocal scanning laser Doppler flowmetry: experiments in a model flow system.

Authors:  B C Chauhan; F M Smith
Journal:  J Glaucoma       Date:  1997-08       Impact factor: 2.503

8.  [A patient with rabies in The Netherlands].

Authors:  H M Schrijver; M M Veering; M M Vis
Journal:  Ned Tijdschr Geneeskd       Date:  1997-03-01

9.  Two dimensional mapping of the perfusion of the retina and optic nerve head.

Authors:  G Michelson; B Schmauss
Journal:  Br J Ophthalmol       Date:  1995-12       Impact factor: 4.638

View more
  10 in total

1.  The effect of image alignment on capillary blood flow measurement of the neuroretinal rim using the Heidelberg retina flowmeter.

Authors:  M Sehi; J G Flanagan
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

2.  Reproducibility of the Heidelberg retinal flowmeter in determining low perfusion areas in peripapillary retina.

Authors:  C P Jonescu-Cuypers; A Harris; R Wilson; L Kagemann; L V Mavroudis; F Topouzis; A L Coleman
Journal:  Br J Ophthalmol       Date:  2004-10       Impact factor: 4.638

3.  Reproducibility of circadian retinal and optic nerve head blood flow measurements by Heidelberg retina flowmetry.

Authors:  C P Jonescu-Cuypers; A Harris; K U Bartz-Schmidt; L Kagemann; A S Boros; U E Heimann; B H Lenz; R-D Hilgers; G K Krieglstein
Journal:  Br J Ophthalmol       Date:  2004-03       Impact factor: 4.638

4.  Impact of simulated light scatter on scanning laser Doppler flowmetry.

Authors:  S T Venkataraman; C Hudson; E Harvey; J G Flanagan
Journal:  Br J Ophthalmol       Date:  2005-09       Impact factor: 4.638

5.  Quantitative optical coherence tomography angiography of choroidal neovascularization in age-related macular degeneration.

Authors:  Yali Jia; Steven T Bailey; David J Wilson; Ou Tan; Michael L Klein; Christina J Flaxel; Benjamin Potsaid; Jonathan J Liu; Chen D Lu; Martin F Kraus; James G Fujimoto; David Huang
Journal:  Ophthalmology       Date:  2014-03-27       Impact factor: 12.079

6.  Retinal blood flow measurements and neuroretinal rim damage in glaucoma.

Authors:  J F J Logan; S J A Rankin; A J Jackson
Journal:  Br J Ophthalmol       Date:  2004-08       Impact factor: 4.638

7.  Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography.

Authors:  Yimin Wang; Bradley A Bower; Joseph A Izatt; Ou Tan; David Huang
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

8.  Measurement of total blood flow in the normal human retina using Doppler Fourier-domain optical coherence tomography.

Authors:  Y Wang; A Lu; J Gil-Flamer; O Tan; J A Izatt; D Huang
Journal:  Br J Ophthalmol       Date:  2009-01-23       Impact factor: 4.638

9.  Quantitative OCT angiography of optic nerve head blood flow.

Authors:  Yali Jia; John C Morrison; Jason Tokayer; Ou Tan; Lorinna Lombardi; Bernhard Baumann; Chen D Lu; Woojhon Choi; James G Fujimoto; David Huang
Journal:  Biomed Opt Express       Date:  2012-11-07       Impact factor: 3.732

10.  Optic Disc Vascularization in Glaucoma: Value of Spectral-Domain Optical Coherence Tomography Angiography.

Authors:  Pierre-Maxime Lévêque; Pierre Zéboulon; Emmanuelle Brasnu; Christophe Baudouin; Antoine Labbé
Journal:  J Ophthalmol       Date:  2016-02-22       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.