Literature DB >> 1122216

[New functions and variables to characterize and compare vectorcardiograms (author's transl)].

W Koch, H Schaefer.   

Abstract

1. The variability of electrographic data used up to now is too large to discriminate easily between normal and abnormal. 2. This variability is partly caused by errors in the measuring process and its consequences. A sepcial difficulty is found in determining the beginning and the end of QRS, so that instantaneous vector magnitudes related to the starting or ending moment of QRS will have a high variance and therefore a low comparability. Displacements of the heart will play an important role as a source of errors. 3. It therefore seems to be more appropriate to describe structure and changes in time of the vector loop. To this end 3 new functions v, w and u are described, all three invariant towards positional changes of the heart in space. The term v means a time-dependent function describing the first derivative of the length of the instantaneous resulting vector of all electrical sources. The term w indicates the projection of the first derivative of the instantaneous vector into a plane orthogonal to the resulting vector. Therefore, v is dependent on the change of all resulting electrical forces, whereas w is the velocity of the peak of the resulting vector on its way along the vector loop. The interpretation of u is complicated; u is a measure of how much the vector leaves a plane, in which it normally more or less remains; u is therefore a measure for the edgeside view of the vector loop. 4 These data are combined with the well-known vectorial data to form a system of vectorial description. 5 The interpretability of these data in physiological terms is exemplified. The description presented here allows to go back to cardiac processes in the proper sense and to largely elimenate external influences like those of the thoracic shape on the ecg and vcg. 6. This way of describing an ecg is specially adapted to the discrimination of normal and abnormal in preventive tests.

Mesh:

Year:  1975        PMID: 1122216     DOI: 10.1007/bf01905557

Source DB:  PubMed          Journal:  Basic Res Cardiol        ISSN: 0300-8428            Impact factor:   17.165


  6 in total

1.  [Data reduction, smoothing and base line correction preceding an automatic evaluation of ECG signals (author's transl)].

Authors:  W Koch
Journal:  Basic Res Cardiol       Date:  1975 May-Jun       Impact factor: 17.165

2.  [The variability of the QRS loop in the orthogonal lead system of frank and schmitt (SVEC III) (author's transl)].

Authors:  W D Hiltmann
Journal:  Basic Res Cardiol       Date:  1975 Jan-Feb       Impact factor: 17.165

3.  [Theory of methods to compare lead fields in electrocardiography (author's transl)].

Authors:  W D Hiltmann; H Schaefer
Journal:  Basic Res Cardiol       Date:  1975 Jan-Feb       Impact factor: 17.165

4.  Multigroup diagnosis of electrocardiograms.

Authors:  J Cornfield; R A Dunn; C D Batchlor; H V Pipberger
Journal:  Comput Biomed Res       Date:  1973-02

5.  [Study on the accurracy of an automatic ECG measurement system].

Authors:  W Gaus; K Uberla
Journal:  Methods Inf Med       Date:  1973-01       Impact factor: 2.176

6.  [Computer analysis of the corrected orthogonal cardiogram. I. Corrected, orthogonal cardiogram and mathematical definition of vectorcardiographic values].

Authors:  H J von Mengden; K Brodda
Journal:  Arch Kreislaufforsch       Date:  1972-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.